Bank C-6: Set Minimum Delay
Use the following steps to reset both the H Delay and V Delay values to 0
(zero).
1. Select Bank C, and rotate
Function Select
to position 6.
2. Reset all delays as required:
•
Toggle
Mode Select
up
to reset H Delay and V Delay to 0.
Bank SW1 Function Select SW2 Mode Select Heads-Up Display Label Default
C
6
+ Zero
- No action
MIN DEL ZERO
N/A
Bank C- 7: Input Mode
The
Input Mode
function selects what type of video is being input. The choices are:
•
Standard
– standard
•
VTR
– input signals that do not have a stable timebase, such as from VTR’s or
VCR’s
When VTR is selected as the video Input Mode, an external reference is required to reclock the input
signal to the house clock. The external reference provides stable output timing.
Use the following steps to set the Input Mode:
1. Select Bank C, and rotate
Function Select
to position 7.
2. Select the desired Input mode according to the following table.
•
Toggle
Mode Select
up
to set VTR mode
•
Toggle
Mode Select
down
to set STANDARD mode.
Bank SW1 Function Select SW2 Mode Select Heads-Up Display Label Default
C
7
+ VTR mode
- STANDARD mode
IN MODE VTR
STAND
STAND
Note
A reference must be connected when in
VTR Mode
.
Note
A reference must be connected when in
VTR Mode
. This
mode affects the
Hotswitch Mode.
Timebase error-prone
signals such as from a VCR will falsely trigger the hotswitch
detector. Thus, an
Input Mode
selection of VTR will force the
Hotswitch Mode
to OFF.
4-18
•
Using Banks