Bank C-3: H Reset
Use the following steps to reset just the H Delay value to 0 (zero). This function is particularly useful
if your adjustment range is far off the mark, or if you simply want to quickly return to zero.
1. Select Bank C, and rotate
Function Select
to position 3.
2. Reset H Delay as required:
•
Toggle
Mode Select
up
to reset H Delay to 0.
Bank SW1 Function Select SW2 Mode Select Heads-Up Display Label Default
C
3
+ Zero
- No action
H RESET ZERO
N/A
Bank C-4: V Delay
Use the following steps to adjust the output’s V Delay:
1. Select Bank C, and rotate
Function Select
to position 4.
2. Increase or decrease the V Delay as required:
•
Toggle
Mode Select
up
to increase V Delay by one line.
•
Hold
Mode Select
up
to increase V Delay continuously.
•
Toggle
Mode Select
down
to decrease V Delay by one line.
•
Hold
Mode Select
down
to decrease V Delay continuously.
Bank SW1 Function Select SW2 Mode Select Heads-Up Display Label Default
C
4
+ Increase
- Decrease
V DELAY (#)
0
Bank C-5: V Reset
Use the following steps to reset just the V Delay value to 0
(zero).
1. Select Bank C, and rotate
Function Select
to position 5.
2. Reset V Delay as required:
•
Toggle
Mode Select
up
to reset V Delay to 0.
Bank SW1 Function Select SW2 Mode Select Heads-Up Display Label Default
C
5
+ Zero
- No action
V RESET ZERO
N/A
ADC-8032A User Manual (Iss. 04)
Using Banks
•
4-17