12
TROUBLESHOOTING
CAUTION! For all the operations described below, close the gas interception cock and turn
to specialized and authorized personnel who have an adequate knowledge of the functions
of the various parts, and of the precautions to be taken.
Below are listed some possible malfunctions and the likely cause and remedy, if the problem is not
solved, or it is not accounted for in the following table, call our customer technical service.
MALFUNCTION
LIKELY CAUSE
REMEDY
The pilot burner will not ignite.
*Malfunctioning of the spark
plug.
*Insufficient pressure at the pilot
burner.
*Check the spark plug fixing,
*Check the cable and the connec-
tions with the igniter and the spark
plug.
*Check the igniter and spark plug,
and replace if necessary.
*Check the supply pressure
(§2.4.1)
*Check the nozzle and clean it or
replace if necessary.
*Check the valve.
The pilot burner goes out as
soon as the knob is released.
*The pilot burner does not suffi-
ciently heat the thermocouple.
*Insufficient pressure at the
valve.
*Repeat the operation, pressing the
valve knob in more fully.
*Check the relative position of the
pilot and of the thermocouple.
*Check the supply pressure
(§2.4.1)
*Check the valve.
The main burner will not ignite
even if the pilot burner is ignited.
*Insufficient pressure at the
burner.
*Burner holes clogged.
*Check the supply pressure and the
pressure at the nozzle (§2.4.1).
*Check the valve.
*Check the nozzle and clean or
replace it if necessary.
*Clean the burner.