Rosito BisanI CPG Скачать руководство пользователя страница 10

10 

 

PUTTING INTO OPERATION 

5.1 OPERATIONS PRIOR TO STARTING 
 
WARNING! If you do not follow these instructions exactly, a fire or explosion may result, 
causing property damage, personal injury, or loss of life. 
 

Make sure the basin is clean, otherwise clean it as described in paragraph 7.1.  
If you are using the cooker for the first time, you need to thoroughly clean all the parts that can 
come into contact with foodstuffs. In this case, proceed as follows: 
 

 

Fill the basin with water and ordinary detergent. 

 

Put the machine into operation as described in the following paragraph. 

 

When the water is boiling, wait for a few minutes, and then turn off the flame as described in the 
following paragraph. 

 

Open the door and drain by moving the lever inside into the open position. 

 

Rinse the basin carefully with clean water. 

With ordinary use, the first thing to do is to load with water. 

 

Close the drain by moving the drain lever onto the closed position. 

 

Turn knob 1 of figure 3 anticlockwise. 

 

Wait for the basin to fill up to the top notch and then close the inlet cock by turning knob 1 of fig-
ure 3 clockwise. 

 
CAUTION! Do not leave the cooker in operation with no water in the basin. 

When lighting the pilot, follow these instructions exactly: 
1.  BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the 

floor because some gas is heavier than air and will settle on the floor. If you smell gas, you must 
follow the instructions placed in front view of the appliance. 

2.  Never use tools to push in or turn the gas control knob. If it will not push in or turn by hand, don’t 

try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or 
explosion.  

3.  Don’t use this appliance if any part has been under water. Call a qualified service technician to 

inspect the appliance and to replace any part which has been under water. 

 
5.2 LIGHTING AND SHUTDOWN INSTRUCTIONS 
 

1.  Carry out the procedures prior to putting the cooker into operation given in the above paragraph. 
 

CAUTION: fill the cooker basin with water up to the top reference notch.

 

2.  Open the gas interception cock, located upstream of the machine. 
3.  Turn the knob of valve (pos.2 in fig. 3) onto the OFF position and wait 5 minutes to clear out any 

gas. If you smell gas, you must follow the instructions placed in front view of the appliance.  

4.  Turn the knob of the valve (pos. 2 in fig. 3) onto the PILOT position (pos. 1 in fig 3a). Open the 

door. 

5.  Push the knob fully in and hold in, wait a few seconds and put a flame near the ignition pipe 

(see Fig.5a) until the pilot flame ignites, which may be seen through the slot on the frame. Wait 
for a few seconds and release the knob.  If the flame fails to stay alight, repeat this operation. 
ATTENTION: you must not put the flame into the pipe, but only near the edge of the ignition 
pipe.  

6.  Turn knob 2 of figure 3 onto a position between the minimum and maximum ones (2 and 3 of fig. 

3a), choosing the optimum value in relation to the quantity of product to be cooked. 

7.  Close the door and load the basket with the pasta to be cooked. 

PUTTING INTO OPERATION 

Содержание CPG

Страница 1: ...FAX 510 785 3342 Gas Cooker ROSITO BISANI MODEL CPG Keep area around appliances free and clear from combustibles PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE These instructions should be read thoroughly before attempting installation Set up and installation should be performed by qualified installation personnel ...

Страница 2: ...up and adjusting 6 2 4 2 Checks 7 3 USER INSTRUCTIONS 8 4 SPECIFICATIONS 9 5 PUTTING INTO OPERATION 10 5 1 Operations prior to starting 10 5 2 Lighting and shutdown instructions 10 5 3 Instructions to prevent accidents 11 6 TROUBLE SHOOTING 12 7 CLEANING AND MAINTENANCE INSTRUCTIONS 13 7 1 Special Maintenance 13 7 1 1 Replacing the main burner 13 7 1 2 Replacing the pilot burner 14 7 1 3 Replacing...

Страница 3: ...inspected and packed by skilled personnel before leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of this shipment If shipment arrives damaged 1 VISIBLE LOSS OR DAMAGE Be certain this is noted on freight bill or express receipt and signed by person making delivery 2 FILE CLAIM FOR DAMAGES IMMEDIATELY Regardless of the extent of damage 3 C...

Страница 4: ...ke certain that the air intake openings in the bottom of the appliance are not obstructed They are essential for proper combustion and operation of the appliance Maintain adequate clearance in front of unit for servicing and proper operation NOTE All servicing can be done through the front door THIS APPLIANCE IS EQUIPPED FOR NATURAL GAS with orifices sized for operation with natural gas This equip...

Страница 5: ... unit must operate in a level position Slight floor irregularities can be compensated by turning the adjustable feet of the cooker either clockwise or counterclockwise Clearances from combustible and noncombustible construction are give in table 1 2 Table 1 1 Minimum change of air in relation to the thermal power installed Table 1 2 Clearances from combustible and noncombustible construction 2 2 H...

Страница 6: ...d fitters Make sure the data of the rating plate correspond to the mains values The rating plate is located at the bottom of the screen door panel Having verified that the gas supply system available is adequate you can go ahead with the connection 1 Connect the mains pipe to the machine pipe pos G in fig 1 using a quick closing interception cock which is easy to reach You must use a pressure regu...

Страница 7: ... C 6 Operate the appliance in the maximum conditions for at least 15 minutes and then turn the knob onto the minimum position 7 Turn the minimum adjustment screw pos a in fig 7 to obtain a reduced flame but sufficiently stable and homogeneous 8 Turn off the burner by following the instructions of par 5 2 close the gas interception cock disconnect the pressure gauge screw the closing screw back and...

Страница 8: ...e should be destined only for the use it has been designed for every other use is to be considered improper and therefore unreasonable The manufacturer declines all liability for any damage to persons or things caused by improper erroneous or unreasonable use Any tampering or modification to the appliance that has not previously been authorized by the manufacturer frees the manufacturer from damag...

Страница 9: ...eight 65Kg 101Kg 144Kg 50Kg 93Kg Tank capacity at maximum level 10 6 gal 45l 10 6 10 6 gal 10 6 10 6 10 6 gal 7 4 gal 28l 7 4 7 4 gal Gas supply mains connection Φ1 2 Water mains connection Φ1 2 Water outlet connection Φ 1 Rated thermal power 60000 BTU hr 120000 BTU hr 180000 BTU hr 31000 BTU hr 62000 BTU hr Thermal power at minimum 13000 BTU hr 26000 BTU hr 39000 BTU hr 13000 BTU hr 26000 BTU hr ...

Страница 10: ...laced in front view of the appliance 2 Never use tools to push in or turn the gas control knob If it will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion 3 Don t use this appliance if any part has been under water Call a qualified service technician to inspect the appliance and to replace any part wh...

Страница 11: ...cified in this manual If the operator has not been sufficiently well trained operation will not be optimum and the risks concerning safety will increase It is compulsory to Fill the basin with water up to a level between the two notches Carry out all the routine maintenance and cleaning operations listed below Keep the surfaces that can come into contact with foodstuffs clean Make sure the gas pip...

Страница 12: ... the connec tions with the igniter and the spark plug Check the igniter and spark plug and replace if necessary Check the supply pressure 2 4 1 Check the nozzle and clean it or replace if necessary Check the valve The pilot burner goes out as soon as the knob is released The pilot burner does not suffi ciently heat the thermocouple Insufficient pressure at the valve Repeat the operation pressing t...

Страница 13: ...them and air the rooms periodically The periodic annual maintenance of the burners must be done by specialized and authorized personnel and it consists of keeping the holes clean for the fuel comburent mixture to flow in and out Access to the burners and nozzles is explained in the following paragraphs 7 1 Special Maintenance The special maintenance procedures should be carried out by qualified an...

Страница 14: ...cock 1 After making sure you have cut off the gas supply remove the door by unscrewing the screw fixing it to the support 2 Remove the water inlet knob 1 of fig 3 and unscrew the two screws fixing the instrument pan el to the under panel Remove the instrument panel 3 Disconnect from the valve from the supply pipe the pipe that goes to the burner and the one that goes to the pilot burner and the th...

Страница 15: ...15 DIAGRAM ...

Страница 16: ...16 DIAGRAM ...

Страница 17: ...17 DIAGRAM ...

Страница 18: ...18 DIAGRAM ...

Страница 19: ...19 DIAGRAM ...

Страница 20: ...20 DIAGRAM ...

Страница 21: ...21 DIAGRAM ...

Страница 22: ...22 DIAGRAM ...

Страница 23: ... adjusted for the manifold pressure marked on the rating plate 5 Adequate air supply to the unit 6 The equipment is operated in the manner intended using the proper utensil for that type of appliance 7 Keep the equipment clean and have it checked periodically 8 Burner air adjustments mechanical maintenance and repairs should be performed by qualified service personnel If the equipment is not insta...

Страница 24: ...ing information Serial No _____________________________________________ Model No _____________________________________________ Change No ____________________________________________ Name No of Part Model No Change No Serial No The Montague Company 1830 Stearman Avenue P O Box 4954 Hayward CA 94540 4954 ...

Отзывы: