background image

   

 

User Manual: Wireless Access Point

 

 

2

 / 

16

 

 

FCC Caution:

 

This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is  subject  to  the 
following two conditions: (1) This device may not cause harmful interference, and (2) 
this  device  must  accept  any  interference  received,  including  interference  that  may 
cause undesired operation. 

Non-modification Statement:

 

Changes  or  modifications  not  expressly  approved  by  the  party  responsible  for 
compliance could void the user's authority to operate the equipment. 
 

NOTICE 

This  document  is  intended  for  system  integrators  to  provide  operation  guidance. 
Please read carefully before using. 
It  should  be  known  that  before  the  sensor  installing,  the  Wireless  Access  Point  is 
required  to  be  installed  previously,  considering  the  verifying  of  the  sensor  online 
status depends on the network established by them. 
Keep  away  from  fire,  strong  electric  field,  strong  magnetic  field,  and  avoid  strong 
shock, otherwise a permanent damage might be caused. 
Do not take apart without permission, as it may cause damage to the product.. 
Please note that in this document, the Wireless Vehicle Detector (WVD) is also called 
Sensor, the Wireless Access Point (WAP) is also called Collector or shorted in AP. 
 

VERSION 

V2.00 2014.8.25 

 

Содержание WAP-348 Series

Страница 1: ... not responsible for the personal security of products installation ROSIM reserves all the rights of final interpretation Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference i...

Страница 2: ...nt is intended for system integrators to provide operation guidance Please read carefully before using It should be known that before the sensor installing the Wireless Access Point is required to be installed previously considering the verifying of the sensor online status depends on the network established by them Keep away from fire strong electric field strong magnetic field and avoid strong s...

Страница 3: ...ager 10 5 3 Data transmission 10 5 4 Detection indication 11 5 5 Detection result output 11 5 6 Region filter 11 5 7 GPRS communication 11 5 8 PoE 12 6 Specifications 12 7 Accessories 12 8 Configuration 13 9 Installation 13 9 1 Antenna install 13 9 2 Output terminals 14 9 3 GPRS antenna connection 14 9 4 Set the configuration 14 9 5 Data communication 15 9 6 Power supply 15 9 7 Run indicator 15 10...

Страница 4: ...etween host platform and WVDs And also the WAP 348X runs the system algorithm and outputs control signal according to different applications 2 Dimension 3 Application ROSIM provides various types of WAP products that can be used in many kinds of traffic systems like signal light optimization traffic flow monitoring travel information guidance and red light and speed enforcement etc Please select t...

Страница 5: ...ed as the following table Status of LED Description Off No WVD is bound to this LED or the WVD is out of work Red A vehicle is detected by WVD installed in this channel Green No vehicle detected Green flash WVD warning If there is no WVD or the WVD has not connected to the WAP 348X the corresponding LED will be OFF In this situation customers need to check whether the WVD out of works If the statu...

Страница 6: ... 4 USB The USB port is mainly used for purpose of maintenance and debug but also can be used as a date transmission interface Note that this USB port is a virtual serial port with baud rate 115200bps 8 digit bits 1 digit stop bit and no parity bit 5 ON OFF Power ON OFF of WAP 348X 6 Work indication Indication LED Description RUN LED Indicating WAP 348X communicate status Once WAP 348X receives wir...

Страница 7: ...he WAP 348X is powered by an external 9 12V 2A DC supply It is recommended for users to use manufacturer original power supply adapter If a special power adapter is needed please select adapters with DC12V and at least 2A output The input voltage range of adapter depends on the power supply that can be available from the roadside case Please note that the plug s outer ring diameter is 5 5 mm inner...

Страница 8: ...AN where WAP is connected The Server IP and port name should be set according to the server IP where user applications run But if a demo system is expected by connecting WAP to a PC directly a cross Ethernet cable should be used After Ethernet IP being configured the LAN port could also be used for system configuration as mini USB port 5 Signal outputs WAP 348X has 48 output terminals in the rear ...

Страница 9: ...y default It can be customized The power supply of the inner pull up is the DC12V supply of WAP 348X The peak sink current of each single terminal is 500mA and the average current of all the 48 terminals is 70mA It is recommended that the pull up power supply should not exceed DC36V and the sink driving current of each single terminal should not exceed 70mA 6 Serial port WAP 348X provides a standa...

Страница 10: ...y to bind all the ID of WVDs to a WAP 348X if these WVDs are ready to use together with this WAP 348X in one application site 5 3 Data transmission The WAP 348X acts as a gateway of the local wireless sensor network It is responsible for data exchange between the local network and external systems WAP 348X provides system integrator a variety of data communication interface including RS 232 serial...

Страница 11: ...bind the WAP 348X to all WVDs within the network so that these WVDs will only communicate with this bound WAP 348X and this WAP 348X will not accept any other data from WVDs which are installed in other regions This feature can be achieved through configuring the region filter function of WAP 348X by the SensorManager software in which all the WVDs can be bound to the WAP 348X by their IDs Only th...

Страница 12: ...Power supply DC9 36V Output signal 48 OCs Output logic Configurable Product size Length 230 Width 100 High 49 mm Operation temperature 40 85 Storage temperature 40 85 7 Accessories ROSIM provides two kinds of antenna for customers The Yagi directional antenna is usually suitable for application site where the communication distance between WAP 348X and each sensor are long While the whip antenna w...

Страница 13: ...nna should be installed in the position where all the WVDs could be covered by the RF signal As is recommended in the following picture the positions 1 2 3 and 4 are equivalent in this figure so any of them would be suitable for antenna installing For most applications a lamppost is suitable to install the antenna if it is near the case and the power supply is available Or else a pole should be se...

Страница 14: ...ust remain them disconnected Each output terminal is an OC output inside the WAP 348X External circuits may require the use of appropriate pull up resistors and the pulling voltage level can be DC9 36V 9 3 GPRS antenna connection Some type of WAP 348X provides GPRS function which provides system integrator a solution with high integration low cost and low price User should prepare a SIM card with ...

Страница 15: ... inside the equipment is expected to be used two power lines are needed to connect it to the power input terminals in rear panel of WAP 348X Note that these two sockets are connected together inside WAP 348X so they are functional equivalent 9 7 Run indicator Power on the WAP 348X by pushing the switch to ON side after the power supply line is connected At this time the SYS and RUN LED are lightin...

Страница 16: ...8 LEDs are off now These LEDs will be needed to verify the communication link between WAP 348X and each WVD when installing the WVDs and to confirm whether the installed WVDs are working regularly as well 10 Supports ROSIM creates and manufactures high quality wireless parking detection devices We provide customers 24 hours on line supports Rosim ITS Technology Co Ltd Tel 86 760 85313186 Mob 86 13...

Отзывы: