background image

   

 

User Manual: Wireless Access Point

 

 

10

 / 

16

 

 

7)

 

Net antenna 

Net antenna interface is used to connect with an external antenna. WAP-348X uses 
this  antenna  to  communication  with  all  the  WVD  sensors  that  are  installed  in  the 
application site. 

5.

 

Functions 

5.1.

 

Information collection 

WAP-348X  collects  all  the  information  detected  by  WVDs  installed  on  each  lane  of 
the  road.  The  information  is  then  transmitted  immediately  and  simultaneously  to 
host  system  through  serial  port,  USB  port  and  Ethernet  port  if  available,  as  well  as 
signal terminals. WAP-348X supports 48 channels of information collection at most. 
Each channel is relevant to a WVD.   

5.2.

 

Network manager 

As  a  gateway of  local  wireless  sensor network,  besides of  collecting  and processing 
all  the  sensor  data,  WAP-348X  manages  and  maintains  the  network  to  guarantee 
data  communication  in  real  time  and  correctly.  WAP-348X  also  accepts  commands 
from host system and transmits them to WVD. A WAP-348X can manage 48 WVDs at 
most.  It  is  necessary  to  bind  all  the  ID  of  WVDs  to  a  WAP-348X  if  these  WVDs  are 
ready to use together with this WAP-348X in one application site. 

5.3.

 

Data transmission 

The  WAP-348X  acts  as  a  gateway  of  the  local  wireless  sensor  network.  It  is 
responsible  for  data  exchange  between  the  local  network  and  external  systems. 
WAP-348X  provides  system  integrator  a  variety  of  data  communication  interface 
including RS-232 serial port, USB port, 10/100Mbps Base Ethernet port and GPRS as 
well. All these data interface ports are functionally equivalent and data output from 
them simultaneously when used as data output port connecting to user system. The 
RS-232 port and Ethernet port is mainly used for detection result information output 
to user system, while the USB port is mainly used for detection system configuration 
as well as detection result output for purpose of monitoring. Besides of using as data 
transmission  to  user  system,  the  Ethernet  port could  also  be  used  to  connect  WAP 
with PC for configuration. But because the LAN port will not be available until the IP 
configuration  is  set  successfully,  if  it  is  the  first  time  to  use  WAP,  the  configuration 
can only be implemented through the USB port of WAP. 

Содержание WAP-348 Series

Страница 1: ... not responsible for the personal security of products installation ROSIM reserves all the rights of final interpretation Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference i...

Страница 2: ...nt is intended for system integrators to provide operation guidance Please read carefully before using It should be known that before the sensor installing the Wireless Access Point is required to be installed previously considering the verifying of the sensor online status depends on the network established by them Keep away from fire strong electric field strong magnetic field and avoid strong s...

Страница 3: ...ager 10 5 3 Data transmission 10 5 4 Detection indication 11 5 5 Detection result output 11 5 6 Region filter 11 5 7 GPRS communication 11 5 8 PoE 12 6 Specifications 12 7 Accessories 12 8 Configuration 13 9 Installation 13 9 1 Antenna install 13 9 2 Output terminals 14 9 3 GPRS antenna connection 14 9 4 Set the configuration 14 9 5 Data communication 15 9 6 Power supply 15 9 7 Run indicator 15 10...

Страница 4: ...etween host platform and WVDs And also the WAP 348X runs the system algorithm and outputs control signal according to different applications 2 Dimension 3 Application ROSIM provides various types of WAP products that can be used in many kinds of traffic systems like signal light optimization traffic flow monitoring travel information guidance and red light and speed enforcement etc Please select t...

Страница 5: ...ed as the following table Status of LED Description Off No WVD is bound to this LED or the WVD is out of work Red A vehicle is detected by WVD installed in this channel Green No vehicle detected Green flash WVD warning If there is no WVD or the WVD has not connected to the WAP 348X the corresponding LED will be OFF In this situation customers need to check whether the WVD out of works If the statu...

Страница 6: ... 4 USB The USB port is mainly used for purpose of maintenance and debug but also can be used as a date transmission interface Note that this USB port is a virtual serial port with baud rate 115200bps 8 digit bits 1 digit stop bit and no parity bit 5 ON OFF Power ON OFF of WAP 348X 6 Work indication Indication LED Description RUN LED Indicating WAP 348X communicate status Once WAP 348X receives wir...

Страница 7: ...he WAP 348X is powered by an external 9 12V 2A DC supply It is recommended for users to use manufacturer original power supply adapter If a special power adapter is needed please select adapters with DC12V and at least 2A output The input voltage range of adapter depends on the power supply that can be available from the roadside case Please note that the plug s outer ring diameter is 5 5 mm inner...

Страница 8: ...AN where WAP is connected The Server IP and port name should be set according to the server IP where user applications run But if a demo system is expected by connecting WAP to a PC directly a cross Ethernet cable should be used After Ethernet IP being configured the LAN port could also be used for system configuration as mini USB port 5 Signal outputs WAP 348X has 48 output terminals in the rear ...

Страница 9: ...y default It can be customized The power supply of the inner pull up is the DC12V supply of WAP 348X The peak sink current of each single terminal is 500mA and the average current of all the 48 terminals is 70mA It is recommended that the pull up power supply should not exceed DC36V and the sink driving current of each single terminal should not exceed 70mA 6 Serial port WAP 348X provides a standa...

Страница 10: ...y to bind all the ID of WVDs to a WAP 348X if these WVDs are ready to use together with this WAP 348X in one application site 5 3 Data transmission The WAP 348X acts as a gateway of the local wireless sensor network It is responsible for data exchange between the local network and external systems WAP 348X provides system integrator a variety of data communication interface including RS 232 serial...

Страница 11: ...bind the WAP 348X to all WVDs within the network so that these WVDs will only communicate with this bound WAP 348X and this WAP 348X will not accept any other data from WVDs which are installed in other regions This feature can be achieved through configuring the region filter function of WAP 348X by the SensorManager software in which all the WVDs can be bound to the WAP 348X by their IDs Only th...

Страница 12: ...Power supply DC9 36V Output signal 48 OCs Output logic Configurable Product size Length 230 Width 100 High 49 mm Operation temperature 40 85 Storage temperature 40 85 7 Accessories ROSIM provides two kinds of antenna for customers The Yagi directional antenna is usually suitable for application site where the communication distance between WAP 348X and each sensor are long While the whip antenna w...

Страница 13: ...nna should be installed in the position where all the WVDs could be covered by the RF signal As is recommended in the following picture the positions 1 2 3 and 4 are equivalent in this figure so any of them would be suitable for antenna installing For most applications a lamppost is suitable to install the antenna if it is near the case and the power supply is available Or else a pole should be se...

Страница 14: ...ust remain them disconnected Each output terminal is an OC output inside the WAP 348X External circuits may require the use of appropriate pull up resistors and the pulling voltage level can be DC9 36V 9 3 GPRS antenna connection Some type of WAP 348X provides GPRS function which provides system integrator a solution with high integration low cost and low price User should prepare a SIM card with ...

Страница 15: ... inside the equipment is expected to be used two power lines are needed to connect it to the power input terminals in rear panel of WAP 348X Note that these two sockets are connected together inside WAP 348X so they are functional equivalent 9 7 Run indicator Power on the WAP 348X by pushing the switch to ON side after the power supply line is connected At this time the SYS and RUN LED are lightin...

Страница 16: ...8 LEDs are off now These LEDs will be needed to verify the communication link between WAP 348X and each WVD when installing the WVDs and to confirm whether the installed WVDs are working regularly as well 10 Supports ROSIM creates and manufactures high quality wireless parking detection devices We provide customers 24 hours on line supports Rosim ITS Technology Co Ltd Tel 86 760 85313186 Mob 86 13...