background image

 5/8 Port 10/100Mbp Switch

 RC405/406                                   User Manual 

 

 
 
 

 

 

 

6

ƒ

 

Side Panel 

  The side panel of the 5/8Port Switch indicates a AC inlet, which accepts 100-240V 50-60Hz Power adapter. 

 

 

 

Chapter 3:   

 

Hardware Installation 

ƒ

 

Place the Switch on a smooth surface 

ƒ

 

Connect the output of power cord to the AC-inlet of the Switch. 

ƒ

 

Connect other IEEE802.3 compatible network device(Hub ,Switch ,PC) to one port of the Switch using 
Category 3/4/5 UTP/STP cabling. 

ƒ

 

Connect another IEEE802.3 compatible network device (Hub , Switch ,PC) to another port of the Switch 
by following the same process as described in Step3. 

 

Notice: 

The cable distance between the Switch and other IEEE802.3 compatible network device should not exceed 
100 meter. 

Make sure the wiring is correct 

It can be used Category 3/4/5 cable in 10 Mbps operation.    To reliably operate your network at 100Mbps, you 
must use an Unshielded/shielded Twisted-Pair (UTP/STP) Category 5 cable, or better Data Grade cabling.   
While a Category 3 or 4 cable may initially seem to work, it will soon cause data loss. 
All kinds of IEEE802.3 compatible network device (Hub , Switch ,PC)can connect to the Switch by using 
straight-through wires or crossover wires because of Switch’s auto MDIX function.   
 
 

 

Chapter 4:   

 

Hardware Troubleshooting 

This chapter contains information to help you solve problems.    If the Switch is not functioning properly, make 
sure the Switch was set up according to instructions in this manual. 
1.

 

The Power LED is not lit 

Solution: 

a.

 

Check if the AC power cord is well connected. Try to unplug and plug back the power cord 

to the LAN Switch or try another power cord. 

b.

 

Check if the AC power source is in good condition. 

 

Отзывы: