8 Maintenance of the device
8.1 Handling
Only use the PIM Site Analyzer
α
according to the intended purpose and comply with this documentation to
prevent damages.
To prevent damages to the device we recommend using the carrying bag (see chapter “Accessories”) if you
are using the PIM Site Analyzer
α
in the field.
To lift the device up the tower apply the rope on the eyelets. Do not open the device, always ensure it stands
stable, don’t expose it to hard shocks and always make sure that the environmental conditions for usage and
storage are met. Avoid storing uncharged batteries since it can have a negative effect on the batteries
lifetime. Keep all interfaces clean and use protection caps whenever possible.
8.2 Cleaning
Prior to cleaning the product, disconnect it completely from the power supply (e.g. AC supply network or
battery). Use a soft, non-linting cloth to clean the product. Never use chemical cleaning agents such as
alcohol (except Test Port), acetone or diluents for cellulose lacquers. For cleaning the Test Port use
pressurised air or alcohol soaked cotton swaps. Ventilation outlets can be cleaned with pressurized air.
8.3 Calibration & Repair
Note that any repairs or calibration of the device not performed by Rosenberger can
have a negative impact on the flawless operation of the device and will render any
warranty void.
Due to transportation directive, used batteries must be removed and must not be
sent with the device since potentially damaged batteries can cause fire or may ex-
plode. If a shipment contains used batteries, Rosenberger will remove and scrap
them and will replace them with new batteries at customer’s expense
.
To ensure highest precision of measurements, we recommend a calibration interval of 12 months. If you wish
to send back a unit for calibration or repair, for smooth transaction please contact us prior to shipment. Refer
to the last chapter of this manual for global support addresses.
Calibration FAQs
-
Calibration: Calibration of the unit to the values based on factory-provided, initial calibration. Check
for latest Firmware update.
-
Calibration frequency: To ensure highest precision of measurements we recommend a calibration
interval of 12 months.
-
Cycle time: Standard cycle time is 10 working days after receipt of unit.
-
Service options: We are happy to inform about additional service options