3.2 Installation of Standard Definitions 

 
The standard  procedure to install Standard Definitions is to import them from the  USB stick onto 
your  VNA.  As  standard  delivery  data  files  for  Vector  Network  Anaylzer  Families  PNA 
(Keysight/Agilent) and ZVA (Rohde&Schwarz) are included. Data files for other VNA families are 
available  on  request. If  the  specific  data  file  is  not  available,  the  standard  definitions  have  to  be 
installed manually with the provided information from the Standard Definitions Cards. 
 

 

USB-stick

 

The Kit Info Card gives a brief description for the VNAs described above. 
For all others please consult the VNA operating manual. 
 

 

Manual installation

 

The manual installation is a more complex process. Please consult the VNA operating manual. 
Some network analyzers allow a step by step input of the model based standard definitions 
during the VNA calibration without previously loading them. 
 

 

Updating

 

After a re-calibration the standard definitions are optimized on the basis of the actual 
measurements.  
Data files have to be imported like described before. 
For a manual update only the values that have changed have to be modified.  
 

3.3 Standard Definitions file nomenclature 

 
The file  name includes the calibration  kit type,  the  serial number, the type of  standard definitions 
and the date of calibration. The file extension defines the VNA types the file can be used on. For 
further Information see the Application Note AN001. 
 
KitType 

(SN)

_

StdDef

_

CalDate

.

Ext 

 

  KitType 

05CK001-150, 05CK020-150 or customized type 

 

 

(SN) 

Serial number (5 character) enclosed by brackets 

 

 

StdDef 

‘mb’ stands for model based and ‘db’ for data based, refer to 3.1 

 

 

CalDate 

Date of kit calibration, these standard definition relate to 

 

 

Ext   

e.g.  

 

‘ckt’   file can be used on Keysight/Agilent VNAs 

 

 

 

PNA family and compatible ones 

 

‘calkit’  file can be used on Rohde&Schwarz VNAs 

 

ZVA, ZVB, ZVBT, ZNB families and compatible ones 

 

Example file name: 
 

05CK001-150 (BH003)_mb_2020-05-30.calkit 

Содержание 05CK001-150

Страница 1: ...uenztechnik GmbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 17 Dieses Dokument ist urheberrechtlich gesch tzt This document is...

Страница 2: ...Kit Documentation 1 4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installa...

Страница 3: ...ibration kit used Contributing factors are noise linearity and temperature stability of the VNA transmission and reflection stability of a test port cable as well as operator experience and care VNAs...

Страница 4: ...C10S3 1 Calibration load jack 05K150 C10S3 1 Calibration adaptor plug plug 05S121 S20S3 1 Calibration adaptor jack jack 05K121 K20S3 1 Combi wrench 53W011 000 13 mm 14 mm 15 mm 16 mm 1 Torque wrench...

Страница 5: ...n for installing Standard Definitions on a Vector Network Analyzer Calibration Certificate See chapter Calibration Certificate User Manual This document 1 5 Calibration Certificate Each calibration ki...

Страница 6: ...ns are defined for all calibration standards gauges and the torque wrench in the specific data sheets 3 Standard Definitions 3 1 Standard Definitions Standard definitions provide the data needed to ma...

Страница 7: ...a more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously...

Страница 8: ...setting parameters Sweep type linear logarithmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the d...

Страница 9: ...vailable In cases when the two VNA test ports have different connector systems installed e g RPC N 50 and RPC 3 50 UOSM can handle this situation A second calibration kit is needed Calibration Procedu...

Страница 10: ...calibration or repair contact your local Rosenberger sales office 5 4 Extent of Rosenberger Re Calibration Services Every calibration kit sent for re calibration or repair the following services are...

Страница 11: ...ood connector repeatability and its effect on the overall uncertainty of a measurement procedure should encourage careful inspection interface gauging and handling of coaxial connectors Prior to use a...

Страница 12: ...the utmost importance that connectors do not damage the test equipment interfaces to which they are connected Poor performance of many coaxial devices and cable assemblies can often be traced to poor...

Страница 13: ...tical limits should be done in different orientations averaging up to 4 single measurements When a gauge block is used to initially adjust the gauge a torque spanner should be used to tighten up the c...

Страница 14: ...ger com Tel 49 8684 18 0 Email info rosenberger com Page 14 17 Dieses Dokument ist urheberrechtlich gesch tzt This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH Co KG Figure...

Страница 15: ...in which the centre conductor extends beyond the outer conductor mating plane This may result in buckling of the socket contacts or damage to the internal structure of a device due to the axial force...

Страница 16: ...l centre conductors are within the observed pin depth values in Table 2 2 Refer to 4 2 Interface Dimensions and Gaging 5 Carefully align the connectors The male connector centre pin must slip concentr...

Страница 17: ...en disconnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connectin...

Отзывы: