Air Crash Mode
Roof turret RM 60 C - operation with water
- Operate pump in automatic mode (base setting):
◊
The integrated pilot lamp in switch (S54) is off.
- Engage the pump:
◊
Please refer to the "Engaging the Pump" chapter.
- When the pump is engaged the following program starts:
◊
The water tank suction valve opens automatically.
◊
The priming pump is engaged automatically until a pressure
of 2 bar is achieved (visible on water pressure gauge (P6))
and the engine speed increases.
◊
The pump icon (J1) illuminates blue as long as the priming
pump is engaged.
◊
After achieving a pressure of 2 bar the engine speed decrease
to idle.
- Press "START"-switch (S46).
◊
The turret moves automatically to the actual position of the
control handle (20).
◊
The position LED (H65) illuminates when the turret has
reached the control handles position.
- Direct the turret to the desired position by using control handle
(20).
- Open the turret discharge valve:
◊
Press switch (S50) as long as water discharge is desired or
for permanent discharge press switch (S488).
◊
Pump speed is increased automatically to full speed, as soon
as the turret discharge valve is opened.
- To reduce to half discharge rate press switch (S48), the inte-
grated pilot lamp illuminates.
- To generate spray press switch (S49s) or for full jet press switch
(S49f). This can be done whilst fire fighting.
Temporary stopping of turret operation:
- Close turret discharge valve:
◊
Release switch (S50) or press activated switch (S488).
◊
The pump engine will idle.
Stopping of turret operation:
◊
Release switch (S50) or press activated switch (S488).
◊
The pump engine will idle.
◊
Press "STOP"-switch (S47).
The turret moves to it's transport position.
◊
Disengage the pump - please refer to the "Engaging the
Pump" chapter.