4.3.4. Select Switch Active Pulse Width
Use Select Switch Active Pulse Width to set the pulse width of the source select signal.
Pulse width is the amount of time the switch is closed.
From the Technician Menu, press the
▼
soft key to choose
Select Switch Active Pulse
Width
and then
OK
to open the screen, as shown below.
Press the
◄
soft key to decrease the pulse width, or the
►
soft key to increase the pulse
width.
Press the
Set
soft key to set the pulse width and exit the screen. Each increment
changes the pulse width by 50mSec. The maximum pulse width is 1.1 second.
Figure 33 Select Switch Active Pulse Width settings and soft keys
4.3.5. Select Switch Repeat Delay
Use Select Switch Repeat Delay to change the time delay between source select clicks
on the display.
From the Technician Menu, press the
▼
soft key to choose
Select Switch Repeat
Delay
,
and then
OK
to open the screen, as shown below.
Press the
◄
soft key several times to shorten the time delay between repeats, or press
the
►
soft key several times to lengthen the repeat delay time.
Press the
Set
soft key to set the repeat delay time and exit the screen.