Rosemount 8714D Скачать руководство пользователя страница 2

Quick Installation Guide

00825-0100-4764, Rev BA

June 2004

Rosemount 8714D

2

©  2004 Rosemount Inc. All rights reserved. All marks property of owner.

Electronics Trim of an 8712D, 8732C, or 8742C
Magnetic Flowmeter Transmitter

The Rosemount 8714D is a high-precision instrument that supplies a 8712D, 8732C, or 
8742C Magnetic Flowmeter Transmitter with a voltage corresponding exactly to 0.00 ft/s, 
3.00 ft/s, 10.00 ft/s, and 30.00 ft/s. The precise 30.00 ft/s voltage signal may be used to 
recalibrate or verify operation of the transmitter. (This same procedure is used by the factory 
to calibrate the transmitter; it is rarely needed by customers.) 

Perform this procedure only if you believe that transmitter is no longer accurate.

IMPORTANT NOTICE

This installation guide provides basic guidelines for the Rosemount

®

 8714D. It does not 

provide instructions for detailed configuration, diagnostics, maintenance, service, 
troubleshooting. The manual and this QIG are also available electronically on 
www.rosemount.com.

WARNING

Explosions could result in death or serious injury:

 

In an Explosion-proof/Flame-proof installation, do not remove the transmitter covers 
when power is applied to the unit. 

Electrical shock can result in death or serious injury

• Avoid contact with the leads and terminals. High voltage that may be present on leads 

can cause electrical shock.

Rosemount Inc.

8200 Market Boulevard
Chanhassen, MN USA 
55317
T (US) (800) 999-9307
T (Intnl) (952) 906-8888
F (952) 949-7001

Emerson Process Management 
Flow

Groeneveldselaan 6-8
3903 AZ Veenendaal
The Netherlands
T 31 (0) 318 549 549
F 31 (0) 318 549 559

Emerson Process Management 
Asia Pacific Private Limited

1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947/65 6777 0743

4764_revBA_QIG.fm  Page 2  Tuesday, June 22, 2004  1:49 PM

Содержание 8714D

Страница 1: ...00825 0100 4764 Rev BA June 2004 Rosemount 8714D 00825 0100 4764W Start Step 1 Change Transmitter Parameters Step 2 Connect the Rosemount 8714D Step 3 Perform Electronics Trim Step 4 Verify 8714D Calibration Standard Magnetic Flowmeter Simulator ...

Страница 2: ... provides basic guidelines for the Rosemount 8714D It does not provide instructions for detailed configuration diagnostics maintenance service troubleshooting The manual and this QIG are also available electronically on www rosemount com WARNING Explosions could result in death or serious injury In an Explosion proof Flame proof installation do not remove the transmitter covers when power is appli...

Страница 3: ...etailed instructions regarding 8712D 8732C and 8742C Rosemount 8712D Figure 1 Use the six contact Pin terminal plug style wiring assembly Follow the numeric convention for the 8712D so the plugs match the terminal block Rosemount 8732C 8742C Figure 2 Use the two black connector style wiring assembly One connector has four contacts the other has three Remove the electronics side cover furthest away...

Страница 4: ...e original configuration If the reading is not within this range continue to step 8 4 Initiate an electronics trim with the LOI or HART communicator The electronics trim takes about six minutes to complete No transmitter adjustments are required STEP 4 VERIFY ROSEMOUNT 8714D CALIBRATION STANDARD Guidelines for Checking Series 8714D Magnetic Flowmeter Calibration Standard The Rosemount 8714D Magnet...

Страница 5: ...d 11 Set the input current to terminals 1 and 2 at 500 mA 12 Measure and record the average voltage from terminals 18 and 19 over a five minute period 13 Measure and record the average voltage across the 1 ohm resistor 14 Calculate current with V IR where R is the resistor value 15 Divide result from step 12 by step 14 result 16 Add the absolute value steps 8 and 15 and divide by two The value sho...

Страница 6: ...Quick Installation Guide 00825 0100 4764 Rev BA June 2004 Rosemount 8714D 6 ...