Sensor Installation
4.1
Flanged sensors
Gaskets
The sensor requires a gasket at each process connection. The gasket material
must be compatible with the process fluid and operating conditions. Gaskets
are required on each side of a grounding ring (see
Figure 4-1
). All other
applications (including sensors with lining protectors or a grounding
electrode) require only one gasket on each process connection.
Note
Metallic or spiral-wound gaskets should not be used as they will damage the
liner face of the sensor. If spiral wound or metallic gaskets are required for
the application, lining protectors must be used.
Gasket placement for flanged sensors
Figure 4-1:
A. Grounding ring and gasket (optional)
B. Customer-supplied gasket
Bolts
Note
Do not bolt one side at a time. Tighten both sides simultaneously. Example:
1. Snug upstream
Quick Install Guide
November 2017
10
Rosemount 8700 Magnetic Flowmeter Sensor
Содержание 8712E
Страница 1: ...Quick Install Guide 00825 0100 4727 Rev DC November 2017 Rosemount 8700 Magnetic Flowmeter Sensor ...
Страница 7: ...Flow direction arrow Figure 3 2 November 2017 Quick Install Guide Quick Install Guide 7 ...
Страница 23: ...Wiring 8732ES using combination cable Figure 6 2 November 2017 Quick Install Guide Quick Install Guide 23 ...
Страница 25: ...Wiring 8712ES using combination cable Figure 6 4 November 2017 Quick Install Guide Quick Install Guide 25 ...
Страница 27: ...Wiring 8732EM using combination cable Figure 6 6 November 2017 Quick Install Guide Quick Install Guide 27 ...