MODEL 54e pH/ORP
APPENDIX A
ORP CONFIGURATION
ITEM
CHOICES
ORP SETTINGS
USER SETTINGS
PROGRAM LEVEL (Sections A.2 - A.3)
A.
Alarm Setpoints (Section A.2)
1.
Alarm 1 (low action)
-1400 to +1400 mV
-1400 mV
_______
2.
Alarm 2 (high action)
-1400 to +1400 mV
+1400 mV
_______
3.
Alarm 3 (high action)
-1400 to +1400 mV
+1400 mV
_______
B.
Output Setpoints (Section A.3)
1.
Output 1: 4 mA
-1400 to +1400 mV
-1400 mV
_______
2.
Output 1: 20 mA
-1400 to +1400 mV
+1400 mV
_______
3.
Output 2: 4 mA
-15 to 130 °C
0.0 °C
_______
4.
Output 2: 20 mA
-15 to 130 °C
100.0 °C
_______
CONFIGURE LEVEL (Sections 5.5 - 5.9)
A.
Display (Section 5.5)
1.
Measurement type
pH/ORP
ORP
_______
2.
Convention
ORP/Redox
ORP
_______
3.
Temperature Units
°C/°F
°C
_______
4.
Output 1 Units
mA/% of full scale
mA
_______
5.
Output 2 Units
mA/% of full scale
mA
_______
6.
Language
English/Français/Español/Deutsch/Italiano
English
_______
7.
Main display lower left
See Section 5.5
Alarm 1 Setpoint
_______
8.
Main display lower right
See Section 5.5
Alarm 2 Setpoint
_______
9.
Display contrast
0-9 (9 darkest)
5
_______
10. Tests Timeout
On/Off
On
_______
11. Timeout Value
1-60 min
10 min
_______
B.
Outputs (Section 5.6)
1.
Output 1 Control
(a) Output 1 Measurement
Process/Temp/Ref Imp
Process (ORP)
_______
(b) Output 1 Control Mode
Normal/PID
Normal
_______
2.
Output 1 Setup
(a) Current Range
4-20 mA/0-20 mA
4-20 mA
_______
(b) Dampening
0-299 Sec
0 Sec
_______
(c) Hold Mode
Last value/Fixed value
Last value
_______
(d) Fixed Hold Value (if (c) Fixed)
0-22 mA
21 mA
_______
(e) Fault Value
0-22 mA
22 mA
_______
3.
Output 2 Control
(a) Output 2 Measurement
Process/Temp /Ref Imp
Temperature
_______
(b) Output 2 Control Mode
Normal/PID
Normal
_______
4.
Output 2 Setup
(a) Current Range
4-20 mA/0-20 mA
4-20 mA
_______
(b) Dampening
0-255 Sec
0 Sec
_______
(c) Hold Mode
Last value/Fixed value
Last value
_______
(d) Fixed Hold Value (if (c) Fixed)
0-22 mA
21 mA
_______
(e) Fault Value
0-22 mA
22 mA
_______
5. Hold (Outputs and Relays)
Disable/Enable/ 20 min timeout
Disable feature
_______
C.
Alarms (Section 5.7)
1.
Alarm 1 Control
(a) Activation Method
Process/Temp
Process(ORP)
_______
(b) Alarm 1 Control Mode
Normal/TPC
Normal
_______
TABLE A-1. ORP Settings List
Continued on the following page.
71