background image

ENGINEERING STANDARDS

Rosedale Products, Inc.

IOM

Issue Date: 31JUL02

3730 West Liberty Road

7_3_5 Model LCO 6.wpd

Revision: A

Ann Arbor, MI 48103

n:\iom\

Revision Date: 30May2003

Specification No.

7.3.5

PAGE:  2 of 6 

INSTALLATION, OPERATION, & MAINTENANCE MANUAL

Rosedale Engineering Standards are the property of Rosedale Products, Inc.  A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

Products, Inc.) to any individual or firm beyond the intended recipient firm or individual.  Firms of individuals acting contrary to the above may be subject to suit, ineligibility for continued or

future employment, or removal from Rosedale’s "Approved Manufacturers and Specialty Contractors List".

I.

INSTALLATION

Please remove all shipping and crating materials carefully.  Be sure to remove the plugs from the inlet and

outlet openings.  Dispose of all crating materials safely.

The Model 

LCO-6

 Filter unit is capable of having several different piping variations based upon the outlet

style of your unit.  The inlet service line should be connected to the inlet NPT coupling located near the top of

the unit (above basket level).

The outlet service line should be connected to the outlet coupling, located near the middle or bottom of the unit

depending upon the style of your unit (below basket level).

There are two 1/4" NPT ports on the shell of your Model 

LCO-6

 Filter.  These ports can remain plugged or

used for pressure gauges, vents, or special fitting as your application requires.

Some installations require electrical grounding of all equipment, be sure to provide adequate grounding where

necessary.

After completing installation be sure to double check connections for integrity.  Your Model 

LCO-6

 Filter unit

has been factory pressure tested leak free, therefore, any seepage problems usually occur from improper

installation connections.

You are now ready to install the filter basket and bag (if applicable).  Remove cover by loosening the T-bolt

clamp sufficiently to allow removal of the clamp assembly, lift cover to remove.

The next step is to install the strainer or filter bag basket. When a strainer basket is utilized it is recommended

that an o-ring be installed under the rim of the strainer basket to prevent by-pass of unfiltered fluid (specify

basket seal on order).

If your installation requires a filter bag, place bag into the bag basket and insert bag and basket into the housing

making sure the filter bag ring is firmly seated on the I.D. of the housing.  This configuration does not require a

basket seal, the bag ring serves as the seal.

Before replacing cover assembly, inspect cover seal gasket (replacing as necessary).  Replace cover and

securely tighten T-bolt clamp closure to ensure a leak proof seal between cover and housing body.

Your Rosedale Model 

LCO-6

 Filter is now ready for operation!

Содержание LCO-6

Страница 1: ...hall not be distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Approved Manufacturers and Specialty Contractors List INSTALLATION OPERATION AND MAINTENANCE MANUA...

Страница 2: ... level There are two 1 4 NPT ports on the shell of your Model LCO 6 Filter These ports can remain plugged or used for pressure gauges vents or special fitting as your application requires Some installations require electrical grounding of all equipment be sure to provide adequate grounding where necessary After completing installation be sure to double check connections for integrity Your Model LC...

Страница 3: ...mplete opening of inlet service line until desired flow rate is reached Once the desired service flow has been established the filter will operate efficiently until dirty However under no circumstances should more than 15 PSI Differential Pressure through the filter be obtained Operating the filter unit with a high differential may cause filter bags to rupture and or cause damage to filter system ...

Страница 4: ...essary and make sure it is properly seated 10 Reposition cover onto housing install T bolt clamp and securely tighten to ensure a leak proof seal between the cover housing body Your Rosedale Model LCO 6 Filter unit is now ready for operation Refer to filter system start up procedure III SPARE PARTS LIST Your Rosedale Model LCO 6 Filter unit will give many years of reliable service provided periodi...

Страница 5: ...andards are the property of Rosedale Products Inc A Rosedale standard or copy thereof shall not be distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Approved Ma...

Страница 6: ... rosedaleproducts com Important Notice Warranty In the event any Rosedale Products Inc filtration product is found to be defective in material workmanship or not in conformance with any express warranty for a specific purpose Rosedale s only obligation and your exclusive remedy shall be to repair replace or refund the purchase price of such parts or products upon timely notification thereof and su...

Отзывы: