4  THEORY OF OPERATION 

4.1  UNIVERSAL INTERFACE BOARD ASSEMBLY 

 
The schematic diagram of the Universal Interface Board Assembly (Drawing 51-11098) is 
included in the appendix to this manual.  The schematic illustrates the Power Conditioning 
circuits as well as circuits required to decode Focus, Zoom and Exposure commands. This 
drawing also illustrates the elements that make up the Long Line Amplifier driver circuits. 
 
Details of interconnections between the Universal Interface Board and the Mode Selector 
Board assemblies are shown on Wiring Diagram (Drawing 51-11106). 

4.1.1  Reverse Polarity Protection 

 
Power to the CE-X, 36:1 camera is received through pin 3 with respect to pin 1 of 
universal interface connector J1.  CR1 serves as a steering diode to prevent 
damage from accidentally reversed power connections to the camera. 

4.1.2  Automatic Resettable Fuse Protection 

 
RPS1 is a 500 mA “Polyswitch.”  A Polyswitch behaves as a fuse that opens in case 
of a severe current  overload but  then unlike a fuse, closes automatically once 
circuit conditions return to normal. 

4.1.3  Power Conditioning 

 
Capacitor C9 provides filtering of the input power before it is presented to the main 
power input regulator device, XVR1.  This regulator pr10V through J3 pin 4 
to the Camera Module.  XVR1 is actually mounted external to the board on the 
aluminum base plate of the camera in order assure adequate heat dissipation when 
the camera is operated at higher input voltages. 

 

The output of XVR1 is also used as an input to other power circuits: 
 
a) 

Regulator VR1 - Pr5V to the Zoom, Focus, Exposure control 
circuits as well as the microcontroller. 

b) 

U4 - a DC-DC converter that generates negative output then regulated by 
VR2 to provide -6V to the video processing circuits. 

c) 

VR3 - Pr6V to the video processing circuits. 

4.1.4  Standard Control Circuit Operation 

 
The Zoom, Focus, and Exposure control circuits are actuated by dc voltage inputs 
from a remote control unit.  These levels are applied to logic inverter circuits. When 
the bi-polar control mode is selected these circuits detect the polarity of the 

51-17568   REV B 

 

17

Содержание CE-X-36

Страница 1: ...36 1 COLOR ZOOM CAMERA OPERATION AND MAINTENANCE MANUAL SERIAL NUMBER __________ SALES ORDER __________ 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 858 565 8808 www rosys com 51 175...

Страница 2: ...SELECTION 7 2 9 1 Mode Selection 7 3 CAMERA OPERATION 11 3 1 GENERAL 11 3 2 INSTALLATION 11 3 3 EXPOSURE CONTROL 11 3 4 ZOOM CONTROL 12 3 5 FOCUS CONTROL 12 3 6 IMAGE FLIP CONTROL 13 3 7 NEGATIVE COL...

Страница 3: ...5 1 GENERAL 19 5 2 CAMERA DISASSEMBLY 20 5 3 CAMERA OPERATIONAL CHECKS 20 5 4 CAMERA TROUBLESHOOTING 21 6 MAINTENANCE 22 APPENDIX 23 51 17568 REV B III...

Страница 4: ...his warranty shall be governed by the laws of the State of California In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS disc...

Страница 5: ...nstallation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction please contact our agent in your area or conta...

Страница 6: ...CHANGE RECORD REV DESCRIPTION DATE A Initial Release 17JAN08 BAL B SEE EC 02192 10FEB15 SW 51 17568 REV B VI...

Страница 7: ...drawings in the appendix The camera housing is constructed of hard anodized aluminum and is designed to be operated in natural but hostile environments The front window is made of impact resistant op...

Страница 8: ...application of power with reversed polarity In addition circuits on this board generate the camera control commands sent to the zoom camera module in order to achieve control of Focus position Zoom po...

Страница 9: ...length 0 to 5 000 ft 0 to 1524m of RG 59 U or equivalent balanced line cable Zoom Range 36 1 optical 3 4 to 122 4 mm focal length Digital Zoom 12x 432x with optical zoom combined Field of View In Air...

Страница 10: ...Housing Hard Anodized Aluminum Viewing Port Polished Acrylic 2 6 ENVIRONMENTAL Operating Temperature 0 C to 50o C 32 F to 122 F Storage Temperature 20o C to 60o C Depth Rating 70 m 230 ft 2 7 STANDAR...

Страница 11: ...9 BCR Endbell Connector Impulse MHDG 9 BCR Inline Mating Connector Impulse MHDG 9 CCP Right Angle Mating Connector Impulse MHDG 9 CCP RA 1 Figure 4 Impulse MHDG 9 BCR 2 7 4 Impulse MSSJ 10 BCR Endbel...

Страница 12: ...l or any device that can send RS485 messages On these cameras all of the operating functions including focus zoom and exposure can be controlled from the computer through two conductors utilizing stan...

Страница 13: ...or 12V applied to pin 9 for Focus Far Differential 2 line This mode requires simultaneous application of a voltage source both and across two camera input pins For example if the source typically 12 V...

Страница 14: ...switch assemblies on the board labeled S1 and S2 S1 has 8 and S2 has 6 individual switches The ON position is indicated on each switch assembly A tabulation that follows shows the positions of switche...

Страница 15: ...51 17568 REV B 9...

Страница 16: ...BIPOLAR INPUTS SELECTION UNIPOLAR OR DIFFERENTIAL INPUTS S1 1 3 2 8 6 5 4 7 S2 ON 1 3 2 5 4 6 ON S1 1 3 2 8 6 5 4 7 S2 ON 1 3 2 5 4 6 ON SELECTION UNIPOLAR OR DIFFERENTIAL INPUTS 3 2 1 S1 ON 7 4 5 6...

Страница 17: ...on To achieve this wide range the camera achieves Exposure Control through composite operation of the iris video gain and shutter modes For most operations automatic exposure mode is used to optimize...

Страница 18: ...on specific objects operation in a Manual Focus Mode may be required This is achieved by momentarily operating the Focus switch on the remote control unit To restore Automatic Focus Control simultaneo...

Страница 19: ...area like a crack To activate or deactivate this function EXP DEC 12Vdc and FOCUS FAR 12Vdc must be toggled simultaneously As a way of visual acknowledgement whenever this function is activated or de...

Страница 20: ...o access the control 3 9 1 Adjust LLA in Bipolar Unipolar Differential mode Adjusting the LLA is a simple 3 step procedure Step 1 Enter the LLA adjust mode This is performed by simultaneously actuatin...

Страница 21: ...When the LLA adjust mode is exited the video the new setting is saved in the flash memory of the microcontroller interface and the value is retained through power cycles NOTE The LLA setting is saved...

Страница 22: ...and the overlay position is retained through power cycles Upon power up the camera overlay will display the current mode of operation e g BIPOLAR After all settings are displayed the camera overlay wi...

Страница 23: ...ere current overload but then unlike a fuse closes automatically once circuit conditions return to normal 4 1 3 Power Conditioning Capacitor C9 provides filtering of the input power before it is prese...

Страница 24: ...ncludes a schematic of the video amplifier driver stages The video signals from the camera module are received through J3 6 The signals are applied to one side of capacitor C18 through the gain contro...

Страница 25: ...of equipment to connector J2 As described earlier most of the logic inputs to the microcontroller are received from the inverters in device U1 The microcontroller responds to these inputs in achievin...

Страница 26: ...e coax for continuity This is normally Pin 2 on the standard connector and exits the ROS controller on the middle pin of the BNC connector on the rear panel Normal resistance should only be a few ohms...

Страница 27: ...st points to assist in troubleshooting circuits on the board TP6 Black near J6 is the common for all measurements Readings should be as follows Test Point Function Voltage TP1 Red Regulated Power 9 8...

Страница 28: ...tted and all cabling is secured All threads should be carefully inspected for burrs or early signs of galling Small areas of damaged threads may be polished to remove any offending material The thread...

Страница 29: ...APPENDIX CE X 36 1 CAMERA DRAWINGS 51 17565 Top Assembly CE X 36 1 51 17566 Installation CE X 36 1 51 17567 Wiring Diagram CE X 36 1 52 26634 Protocol RS485 Communication UIB 51 17568 REV B 23...

Отзывы: