background image

To restore automatic Exposure Control simultaneously operate the Zoom towards WIDE 
and the Exposure switch towards DECR. 

3.4  ZOOM CONTROL 

 
The zoom lens operates whenever a Zoom switch on a remote control unit is operated 
towards either the Tele or Wide positions.  The zoom function continues as long as the 
switch is depressed, until the lens zoom limit is reached.  Tele operates towards increasing 
focal length settings providing reduced viewing angles with increased magnification of 
objects in the scene.  Wide operation reduces focal length settings increasing viewing 
angles and allows viewing of greater areas of a scene.  
 
When selecting different zoom lens settings the operator should be aware of the change in 
the Minimum Object Distance (MOD) changes as the viewing angle changes.  At the full 
telephoto position in air, the MOD is approximately 60 inches (1.5 m).  At the full Wide 
Angle position in air, the MOD is the front window. 

3.5  FOCUS CONTROL 

 
The CE-X, 36:1 camera is normally energized and normally operated in Auto-Focus mode. 
This provides nearly ideal focusing when the camera is aimed at different scenes and 
tracks while the zoom control is actuated.   In some instances where there are objects in a 
scene at different distances and there is a need for focusing on specific objects, operation 
in a Manual Focus Mode may be required.  This is achieved by momentarily operating the 
Focus switch on the remote control unit. 
 
To restore Automatic Focus Control simultaneously operate the Zoom towards WIDE and 
the Focus switch towards FAR. 
 
Generally, most in-air users are able to stay in Auto-Focus mode all the time.  The one set 
of conditions, which may force the operator to switch into Manual mode, is in trying to view 
a relatively close object that does not have much sharp detail.  This occurs because the 
Auto-Focus system relies on increasing the sharpness of edges in the viewed image in 
order to optimize the focus. 
 
If there are no edges to utilize for this process, the Auto-Focus will not be able to properly 
compensate and may even tend to "hunt" around the optimum focus point.  Focus hunting 
may also be caused by low illumination.  Again, if the camera is unable to properly sharpen 
edges due to insufficient video level, Auto-Focus operation will be less than optimum.  
Switching over to Manual mode and then focusing with the manual remote Focus control is 
the best option. 
 
Underwater users have a special set of problems, which make Auto-Focus operation more 
difficult.  Seawater normally contains particles in suspension and undissolved solids 
(animal, plant life, etc.) that reduce the detail of a viewed image.  If the image does not 
have sharp detail, the Auto-Focus system will have a difficult time obtaining correct focus. 

51-17568   REV B 

 

12

Содержание CE-X-36

Страница 1: ...36 1 COLOR ZOOM CAMERA OPERATION AND MAINTENANCE MANUAL SERIAL NUMBER __________ SALES ORDER __________ 5618 Copley Drive San Diego CA 92111 7902 TEL 858 565 8500 FAX 858 565 8808 www rosys com 51 175...

Страница 2: ...SELECTION 7 2 9 1 Mode Selection 7 3 CAMERA OPERATION 11 3 1 GENERAL 11 3 2 INSTALLATION 11 3 3 EXPOSURE CONTROL 11 3 4 ZOOM CONTROL 12 3 5 FOCUS CONTROL 12 3 6 IMAGE FLIP CONTROL 13 3 7 NEGATIVE COL...

Страница 3: ...5 1 GENERAL 19 5 2 CAMERA DISASSEMBLY 20 5 3 CAMERA OPERATIONAL CHECKS 20 5 4 CAMERA TROUBLESHOOTING 21 6 MAINTENANCE 22 APPENDIX 23 51 17568 REV B III...

Страница 4: ...his warranty shall be governed by the laws of the State of California In the event the defect is determined to be within the terms of this warranty then ROS agrees to repair and or replace at ROS disc...

Страница 5: ...nstallation and or operation of these products If you have any questions or problems with this product that are not covered by this manual or instruction please contact our agent in your area or conta...

Страница 6: ...CHANGE RECORD REV DESCRIPTION DATE A Initial Release 17JAN08 BAL B SEE EC 02192 10FEB15 SW 51 17568 REV B VI...

Страница 7: ...drawings in the appendix The camera housing is constructed of hard anodized aluminum and is designed to be operated in natural but hostile environments The front window is made of impact resistant op...

Страница 8: ...application of power with reversed polarity In addition circuits on this board generate the camera control commands sent to the zoom camera module in order to achieve control of Focus position Zoom po...

Страница 9: ...length 0 to 5 000 ft 0 to 1524m of RG 59 U or equivalent balanced line cable Zoom Range 36 1 optical 3 4 to 122 4 mm focal length Digital Zoom 12x 432x with optical zoom combined Field of View In Air...

Страница 10: ...Housing Hard Anodized Aluminum Viewing Port Polished Acrylic 2 6 ENVIRONMENTAL Operating Temperature 0 C to 50o C 32 F to 122 F Storage Temperature 20o C to 60o C Depth Rating 70 m 230 ft 2 7 STANDAR...

Страница 11: ...9 BCR Endbell Connector Impulse MHDG 9 BCR Inline Mating Connector Impulse MHDG 9 CCP Right Angle Mating Connector Impulse MHDG 9 CCP RA 1 Figure 4 Impulse MHDG 9 BCR 2 7 4 Impulse MSSJ 10 BCR Endbel...

Страница 12: ...l or any device that can send RS485 messages On these cameras all of the operating functions including focus zoom and exposure can be controlled from the computer through two conductors utilizing stan...

Страница 13: ...or 12V applied to pin 9 for Focus Far Differential 2 line This mode requires simultaneous application of a voltage source both and across two camera input pins For example if the source typically 12 V...

Страница 14: ...switch assemblies on the board labeled S1 and S2 S1 has 8 and S2 has 6 individual switches The ON position is indicated on each switch assembly A tabulation that follows shows the positions of switche...

Страница 15: ...51 17568 REV B 9...

Страница 16: ...BIPOLAR INPUTS SELECTION UNIPOLAR OR DIFFERENTIAL INPUTS S1 1 3 2 8 6 5 4 7 S2 ON 1 3 2 5 4 6 ON S1 1 3 2 8 6 5 4 7 S2 ON 1 3 2 5 4 6 ON SELECTION UNIPOLAR OR DIFFERENTIAL INPUTS 3 2 1 S1 ON 7 4 5 6...

Страница 17: ...on To achieve this wide range the camera achieves Exposure Control through composite operation of the iris video gain and shutter modes For most operations automatic exposure mode is used to optimize...

Страница 18: ...on specific objects operation in a Manual Focus Mode may be required This is achieved by momentarily operating the Focus switch on the remote control unit To restore Automatic Focus Control simultaneo...

Страница 19: ...area like a crack To activate or deactivate this function EXP DEC 12Vdc and FOCUS FAR 12Vdc must be toggled simultaneously As a way of visual acknowledgement whenever this function is activated or de...

Страница 20: ...o access the control 3 9 1 Adjust LLA in Bipolar Unipolar Differential mode Adjusting the LLA is a simple 3 step procedure Step 1 Enter the LLA adjust mode This is performed by simultaneously actuatin...

Страница 21: ...When the LLA adjust mode is exited the video the new setting is saved in the flash memory of the microcontroller interface and the value is retained through power cycles NOTE The LLA setting is saved...

Страница 22: ...and the overlay position is retained through power cycles Upon power up the camera overlay will display the current mode of operation e g BIPOLAR After all settings are displayed the camera overlay wi...

Страница 23: ...ere current overload but then unlike a fuse closes automatically once circuit conditions return to normal 4 1 3 Power Conditioning Capacitor C9 provides filtering of the input power before it is prese...

Страница 24: ...ncludes a schematic of the video amplifier driver stages The video signals from the camera module are received through J3 6 The signals are applied to one side of capacitor C18 through the gain contro...

Страница 25: ...of equipment to connector J2 As described earlier most of the logic inputs to the microcontroller are received from the inverters in device U1 The microcontroller responds to these inputs in achievin...

Страница 26: ...e coax for continuity This is normally Pin 2 on the standard connector and exits the ROS controller on the middle pin of the BNC connector on the rear panel Normal resistance should only be a few ohms...

Страница 27: ...st points to assist in troubleshooting circuits on the board TP6 Black near J6 is the common for all measurements Readings should be as follows Test Point Function Voltage TP1 Red Regulated Power 9 8...

Страница 28: ...tted and all cabling is secured All threads should be carefully inspected for burrs or early signs of galling Small areas of damaged threads may be polished to remove any offending material The thread...

Страница 29: ...APPENDIX CE X 36 1 CAMERA DRAWINGS 51 17565 Top Assembly CE X 36 1 51 17566 Installation CE X 36 1 51 17567 Wiring Diagram CE X 36 1 52 26634 Protocol RS485 Communication UIB 51 17568 REV B 23...

Отзывы: