Ropox 4Single Series Скачать руководство пользователя страница 9

 
 

 

 

Page 

9

 

 

 

 

Replacement instructions 

5.1 

Function test 

Once the control has been replaced and before the unit is used, you must always 
perform a full test of all of 

the table’s functions. The same function test must then 

always be performed at least once a year by competent personnel: 

 

5.1.1 

Before testing the battery: 

1.

 

Check that the installation instructions have been followed. 

2.

 

Check that all bolt connections are securely tightened. 

3.

 

Check that all cables have been connected correctly and that the plugs have 
been pushed in completely.  

4.

 

There must be no load on the table. 

5.

 

There must not be any objects or the like that might prevent the table from 
moving within the height setting range. 

 

5.1.2 

Now switch on the battery: 

 

 

 

6.

 

Press the DOWN button and lower the table to the lowest position. Press the 
DOWN button once more and hold it down for an additional 5 seconds to 
reset the control box. Check that the movement takes place in an even, 
controlled way. 

7.

 

Now press the UP button and raise the table to the highest position, and 
make sure that this takes place in an even, controlled way.  

8.

 

If anti-crushing strips are attached beneath the table top, these must be 
tested. 
Press the DOWN button and allow the table to move 2-5 cm while enabling 
the anti-crushing strip at the same

 

time. The table will now stop its downward 

movement, move 1-2 cm upwards and stop. 
Once all the above items have been checked, you can use the table. 
See 

section 9, “Safe operation”.

 

The battery has no standby consumption. This means that in order 
to operate the table, the button needs to be pressed twice, the first 
time in order to activate the battery.

 

 

Содержание 4Single Series

Страница 1: ...4Single Battery User manual Installation instructions This manual must always accompany the product PDF 6065 12 03 2019 ...

Страница 2: ...gmærke er ikke defineret 4 Replacement instructions 6 4 1 Installing the control 8 5 Replacement instructions 9 5 1 Function test 9 6 Safety 10 7 Maintenance 11 7 1 Service forms operation and maintenance 12 7 2 Waste disposal 13 8 CE declaration 14 8 1 EU Declaration of Conformity 14 8 2 Directives and Standards 14 9 Complaints 15 ...

Страница 3: ... home as described in section 2 The 4Single table and the battery pack are not designed for use in damp rooms Users of this product are obliged to observe these instructions It is extremely important that the instructions have been read and understood before the product is used as correct use operation and inspection are crucial for effective safe functionality It is important that you read this m...

Страница 4: ...utput voltage 24V DC Output current limit Max 15A Intermittence Max 10 1 min active 9 min pause Operational capacity Number of lifts when fully loaded min 100 times Max load 40 47013 130 kg evenly distributed over whole frame Speed time of lift Approx 32 mm s approx 10 seconds Heavy load 40 47014 250 kg evenly distributed over whole frame optional extra Speed time of lift Approx 12 mm s approx 25 ...

Страница 5: ...resistor 1 2 96000578 Battery incl charger 1 set 97701 731 Mount for control box and battery 1 set 95091012 Screw ø4 8 x 13 12 30 67840 Control small surface 6 x 3 cm 1 96000629 Split cable for control Used if more than one control required 1 30 67840 Extra control Used if more than one control required 1 3 1 Optional extras ...

Страница 6: ...er to the list of components to make sure that all parts have been included See list of components section 3 Detach all cables leading to and from the control box before replacing the control Picture 1 4 Removing the old control box 1 2 3 4 Installation must always be carried out by competent personnel ...

Страница 7: ...ounting the battery pack Attach the cables supplied and the existing cables to motors anti crushing strips and controls as shown in the diagram below BATTERY CONTROL BOX Charger Anti crushing strip Motor 1 Motor 2 5 6 7 8 ...

Страница 8: ...Page 8 4 1 Installing the control ...

Страница 9: ...n the battery 6 Press the DOWN button and lower the table to the lowest position Press the DOWN button once more and hold it down for an additional 5 seconds to reset the control box Check that the movement takes place in an even controlled way 7 Now press the UP button and raise the table to the highest position and make sure that this takes place in an even controlled way 8 If anti crushing stri...

Страница 10: ...y modification that might affect the function or structure of the table and the battery pack is not permitted Installation service and repairs may only be performed by personnel with the appropriate competence If the battery pack is not installed in accordance with the installation instructions any right to make a claim under warranty may be revoked Only Ropox s original spare parts may be used wh...

Страница 11: ...once more and hold it down for an additional 5 seconds to reset the control box Check that the movement takes place in an even controlled way Check that all leads are correctly fitted and are undamaged Fill in the service form after each inspection See section 7 1 Only Ropox s original spare parts may be used when replacing parts If other spare parts are used any right to make a claim under warran...

Страница 12: ...e Comments Service and maintenance Serial no Date Signature Comments Service and maintenance Serial no Date Signature Comments Service and maintenance Serial no Date Signature Comments Service and maintenance Serial no Date Signature Comments Service and maintenance Serial no Date Signature Comments ...

Страница 13: ... If anti crushing strips are connected check that they are not enabled The frame does not move smoothly If the frame does not move smoothly you must reset it See section 7 Maintenance The table does not move when I press the control Please note that you must press the same button twice to make the table move The first time is to enable the battery the second time you hold down the button for the a...

Страница 14: ...3 4Single Battery Pack rapid 50 47014 4Single Battery Pack heavy load are classified as class I and conform to the following directives and standards 8 2 Directives and Standards For standards and directives with which conformance is achieved please refer to LogicData the supplier of the battery pack Date 13 03 2012 ...

Страница 15: ...mplaints must be directed to the distributor representing Ropox on the market in question Cf Ropox General Terms of Sale and Delivery Ropox A S Ringstedgade 221 DK 4700 Naestved Tel 45 55 75 05 00 Fax 45 55 78 05 50 E mail info ropox dk www ropox dk ...

Отзывы: