3.9 Operation 

Press the up symbol to raise/lift washbasin and to lower, press the downwards symbol. 
The washbasins stops as soon as the control button is released. 

 

Height adjustment using handheld control switch with spiral cable (standard)

 

 
Fixed control switch (option) 

 
 

 

 
 
 

Warning! 

 
The product should always be able to travel the full range of actuation without colliding with 
objects. Failing to do so will compromise the product stability and introduce risk of squeezing 
body parts. 
Special care should be taken in ensuring that no children or adults are sited under the 
product as severe injury from entrapment may occur. 

Содержание 40-44016

Страница 1: ...Ropox Support Washbasin Electric USER MANUAL MOUNTING INSTRUCTION Keep this manual with the product at all times TF 200 01 0048_eng Dato 31 08 2022 PA 2004 00634 ...

Страница 2: ...CTION ADAPTERS 11 4 3 LIST OF COMPONENTS 12 4 4 INSTALLATION OF PRODUCT 14 4 4 1 Support Washbasin Electric left 14 4 4 2 Support Washbasin Electric right 28 5 PERFORMANCE TEST 41 6 SAFETY INSTRUCTIONS 41 7 POSITIONING OF CONTROL SWITCH 42 8 SERVICE AND MAINTENANCE 42 8 1 CLEANING FRAME 42 8 2 CLEANING WASHBASIN 42 8 3 MAINTENANCE 43 8 4 SERVICE SCHEDULE OPERATION AND MAINTENANCE 44 9 FAULT FINDIN...

Страница 3: ...understood before use Always keep this manual in close proximity of the product The use installation and service of this product must be in compliance with this manual to avoid accidents and serious personal injury Never use or handle this product in other ways specified in this manual as it can result in personal safety hazards and or cause damage to the product Persons installing and or using th...

Страница 4: ...ance Cleaning and user maintenance shall not be made by children without supervision Do not use the product if it has defects or have become damaged before being repaired or replaced If the control box makes unusual noise or smells switch off the mains voltage immediately Take care that the cables are not damaged Unplug the mains cable on mobile equipment before it is moved The products must only ...

Страница 5: ...rial number Operating interval of electrically operated equipment The use of electrical height adjustable equipment can run at maximum 2 minutes followed by an 18 minute break Type BF applied part The product complies with IEC 60601 1 requirements to provide protection against electric shock Consult manual for important safety related information warnings and safety precautions Class II double iso...

Страница 6: ... intended for use in special environments as defined by IEC 60601 1 2 Materials in contact with patient Washbasin Frame Mixer tap Synthetic marble composite Welded steel tube St 37 aluminum Chrome Accessories 40 40935 40 44026 40 44040 40 44023 40 44024 Plug with overflow Fixed press pad Mixer tap Cover left Cover right 3 2 Product description The Ropox Support Washbasin is a disability friendly a...

Страница 7: ...sidered intended operator 3 5 Essential performance The product does not have essential performance as the patient and user do not experience any risk in case of loss of product function performance 3 6 Nonclinical functions Height adjusting offers better ergonomics to the user 3 7 Clinical functions The product does not have any clinical functions 3 8 Product dimensions 40 44016 Left ...

Страница 8: ...control switch with spiral cable standard Fixed control switch option Warning The product should always be able to travel the full range of actuation without colliding with objects Failing to do so will compromise the product stability and introduce risk of squeezing body parts Special care should be taken in ensuring that no children or adults are sited under the product as severe injury from ent...

Страница 9: ... cover plates The water supply ends with two 90 stop valves with outside thread Location and optimum orientation as illustrated The stop valves should not protrude more than 90mm 3 5in from the wall owing to the cover plates We recommend positioning of water and drain installations as illustrated All hoses for water and drain installations must be flexible to ensure unhindered movement within the ...

Страница 10: ...ward 40 44017 Note Stop valves pointing upward 252mm 9 9in 175mm 6 9in 130mm 5 1in 297mm 11 7in 252mm 9 9in 135mm 5 3in 133mm 5 2in 60mm 2 3in 60mm 2 3in 50mm 1 9in 50mm 1 9in 130mm 5 1in 66mm 2 6in 250mm 9 8in 140mm 5 5in 244mm 9 6in 60mm 2 3in 145mm 5 7in 196mm 7 7in 110mm 4 3in 145mm 5 7in 50mm 1 9in 71mm 2 8in 155mm 6 1in 80mm 3 1in ...

Страница 11: ... washbasin Coupling piece Extra hose 1 2 1 2 Item No 97001662 1 2 x 1 2 0 5m steel Item No 97001123 1 2 x 1 2 1m plastic Item No 97001120 Drain adapters Drain hose from washbasin Adapter Installation in room not provided No adapter required Ø32mm 1 3in Ø32mm1 3in Ø40mm 1 6in Item No 97001660 Ø40mm 1 6in Ø32mm 1 3in Ø50mm 1 9in Item No 97001661 Ø50mm 1 9in Drain hose extension Drain hose from washb...

Страница 12: ... one Ropox Support Washbasin Electric right 40 44017 40 44010 070 Top plate with washbasin right oriented 1 one Incl Top frame left oriented 1 one Common parts 30 67636 Flexi legs 2 two sets 40 44016 003 Motor bracket 1 one 40 44016 023 Siphon plate 1 one 40 44016 012 Bottom bracket 1 one 97000483 Motor 1 one 40 44016 204 Control box bracket 1 one 97001691 Control box CA30 1 one ...

Страница 13: ...and control 1 one 97001738 Motor cable L 1000mm 1 one 97000429 Blind plugs 3 three 97000427 Control box cable 1 one 97001601 Siphon 1 one 97001125 Connecting hose x 50cm 19 7in 2 two 97001012 Coupling piece 1 2 to 3 8 2 two 97001035 ø32x88 5 angle 2 two 97001162 Flexible drain hose ø32 32 pipe stub 1 one ...

Страница 14: ...cted to the mains the product must be placed in a manner according to power outlets so that the operator will be able to disconnect the product during use in case of an emergency Prior to assembly check that all parts have been provided according to the list of components See list of components 4 4 1 Support Washbasin Electric left 40 44016 Note Make sure the washbasin does not get scratched while...

Страница 15: ...15 TF 200 01 0048_eng 4 x M8x20 2 x M8x20 2 x M5x10 ...

Страница 16: ...16 TF 200 01 0048_eng 2 x M10x20 1 x M10x35 1 x M10 ...

Страница 17: ...17 TF 200 01 0048_eng 1 x M10 1 x M10x35 ...

Страница 18: ...18 TF 200 01 0048_eng 2 x M5x20 ...

Страница 19: ...19 TF 200 01 0048_eng ...

Страница 20: ...20 TF 200 01 0048_eng Mark up for 8x rawlplugs ...

Страница 21: ...01 0048_eng 6 x M8x72 538mm 21 2in 193mm 7 6in 469mm 18 4in 70mm 2 7in 70mm 2 7in 27mm 1 1in 5mm 0 2in NOTE Depending wall type choose other suitable screws as required Max load on upper screws 71 kg 156 lb screw ...

Страница 22: ...22 TF 200 01 0048_eng NOTE Mixer tap is accessories ...

Страница 23: ...mended placement of electrical installation Fixate excess cables 252mm 9 9in 175mm 6 9in 130mm 5 1in 297mm 11 7in 252mm 9 9in 130mm 5 1in 135mm 5 3in 145mm 5 7in 133mm 5 2in 60mm 2 3in 60mm 2 3in 50mm 1 9in 50mm 1 9in 66mm 2 6in ...

Страница 24: ...048_eng Wiring diagram Mounting of covers accessories Adjust the washbasin to its highest and lowest position to make sure the wires and hoses are mounted correctly and do not conflict during the adjustment 2 x M8x72 ...

Страница 25: ...25 TF 200 01 0048_eng 2 x M4x16 ...

Страница 26: ...26 TF 200 01 0048_eng ...

Страница 27: ...27 TF 200 01 0048_eng 3 x M4x16 ...

Страница 28: ...28 TF 200 01 0048_eng 4 4 2 Support Washbasin Electric right 40 44017 Note Make sure the washbasin does not get scratched while upside down ...

Страница 29: ...29 TF 200 01 0048_eng 2 x M5x10 2 x M8x20 1 x M10x35 1 x M10 ...

Страница 30: ...30 TF 200 01 0048_eng 2 x M10x20 ...

Страница 31: ...31 TF 200 01 0048_eng 1 x M10 1 x M10x35 3x M5x10 ...

Страница 32: ...32 TF 200 01 0048_eng ...

Страница 33: ...33 TF 200 01 0048_eng ...

Страница 34: ...34 TF 200 01 0048_eng Mark for 8x anchors ...

Страница 35: ... 200 01 0048_eng 6 x M8x72 469mm 18 4in 538mm 21 2in 193mm 7 6in 27mm 1 1in 70mm 2 7in 5mm 0 2in NOTE Depending wall type choose other suitable screws as required Max load on upper screws 71 kg 156 lb screw ...

Страница 36: ...36 TF 200 01 0048_eng NOTE Mixer tap accessories ...

Страница 37: ...37 TF 200 01 0048_eng Recommended fixation of the hoses and wires 250mm 9 8in 140mm 5 5in 244mm 9 6in 155mm 6 1in 145mm 5 7in 196mm 7 7in 110mm 4 3in 60mm 2 3in 71mm 2 8in 80mm 3 1in 50mm 1 9in ...

Страница 38: ...38 TF 200 01 0048_eng Mounting of covers accessories 2 x M8x72 2 x M4x16 ...

Страница 39: ...39 TF 200 01 0048_eng ...

Страница 40: ...40 TF 200 01 0048_eng 3 x M4x16 ...

Страница 41: ...of Ropox Support Washbasin Electric should only be operated by persons who have read and understood these instructions Do not use Ropox Support Washbasin Electric as a lifting table or person lifter Always use the washbasin in a manner excluding the risk of damage to persons or property The person operating the washbasin is responsible for avoiding damage or injury If the washbasin is used in publ...

Страница 42: ...reous deposits may occur Remove these calcareous deposits once a week with a cleaning agent containing citric acid ethanoic acid or phosphoric acid Leave the cleaning agent for 5 10 minutes depending on the thickness of the deposits and clean with a soft sponge Disinfection of the washbasin may be made using standard disinfectants Note Do not use cleaning agents containing abrasive e g scouring po...

Страница 43: ... moving parts have been lubricated for life For reasons of safety and reliability we recommend inspection of the frame once a year During inspections Check that all bolts have been tightened Check that the frame moves freely from bottom to top position without problems Resetting the washbasin Press DOWN on the control switch and move the frame to bottom position Press DOWN once more and keep the s...

Страница 44: ...ate Signature Remarks Service and maintenance Serial No Date Signature Remarks Service and maintenance Serial No Date Signature Remarks Service and maintenance Serial No Date Signature Remarks Service and maintenance Serial No Date Signature Remarks Service and maintenance Serial No Date Signature Remarks Service and maintenance Serial No Date Signature Remarks ...

Страница 45: ...it the motor is overloaded note 2 min operation 2 min pause Control switch defective Check whether the height adjustment works with another control switch When pressing the UP and DOWN buttons you only hear clicks from the control unit the washbasin does not move The plugs may not have been inserted correctly Dismount all cables from the control unit and insert them again Resetting may be required...

Страница 46: ...cked use Warning Use of this equipment adjacent to or stacked with other equipment should be voided because it could result in improper operation If such use is necessary this equipment and the other equipment should be observed to verify that they are operating normally 12 3 Cables Cable component Length Power cable 3 2m Hand control spiral cable Approx 5m extended Warning Use of accessories tran...

Страница 47: ... TF 200 01 0048_eng 13 Complaints See General Terms of Sale and Delivery on www ropox com ROPOX A S Ringstedgade 221 DK 4700 Næstved Tel 45 55 75 05 00 Fax 45 55 75 05 50 E mail info ropox dk www ropox dk ...