Controller functions
Page 64
RES-440
Version 1
10.23 Time control (timer function)
10.23.1 Activation and indication
The settings described here are only allowed to be entered by technically trained persons. An incor-
rectly parameterized timer function may cause disruptions to operation and damage to the machine.
The timer function is activated with step 209 [26] in the Configuration menu. There are two possible settings in this
menu:
1.
"OFF" (Factory setting)
Time control (timer function) deactivated
2.
"ON"
Time control (timer function) activated.
The internal timeout is started by activating the "START" signal. The timeout either ends with the parameterized
cooling phase or is interrupted by activating the "RESET" signal.
3.
"ON with START monitoring"
(Software revision 021 or higher)
Time control (timer function) activated and "START" signal monitored.
Once again, the internal timeout is started by activating the "START" signal. In this setting, however, the
"START" signal must remain activated until the end of the parameterized cooling phase. If the "START" signal
is deactivated before the end of the cooling phase - or if the "RESET" signal is activated - the timeout is inter-
rupted.
If time control is on, activating the "START" signal starts the internally parameterized timeout. This timeout com-
prises:
• Starting delay (delay at the beginning of the heating phase)
• Heating phase (heating and control process)
• Cooling phase
• Relay K1 function
!