Controller functions
Page 36
RES-408
Version 1
11.5
Menu steps
Name
Description
Setting range
°C
Home position
The current actual value appears on the terminal
display. The heatsealing band can be heated man-
ually (to the specified heatsealing or preheat tem-
perature) by pressing the "HAND" key.
HA
[
HA
nd]
Hand menu
The heatsealing band can be heated manually (to
the specified heatsealing or preheat temperature)
by pressing the "HAND" key.
This menu step is only available on con-
trollers
manufactured
up
to
December 2000.
SH
[
S
eal
H
eat]
Heatsealing tem-
perature
The required heatsealing temperature (set point)
can be set with the "UP" and "DOWN" keys.
Controllers manufactured up to May 2006:
The maximum selectable set point is limited by the
controller version (300°C or 500°C).
Controllers manufactured as of June 2006:
The maximum selectable set point is limited by the
rotary coding switch (alloy/range) and/or the PC vis-
ualization software.
Controllers manufactured
up to May 2006:
0…300°C or 0…500°C
Controllers manufactured
as of June 2006:
0, 40°C…maximum tem-
perature
PH
[
P
re
H
eat]
Preheat tempera-
ture
The required preheat temperature (PREHEAT) can
be set with the "UP" and "DOWN" keys.
Controllers manufactured up to May 2006:
The preheat temperature must always be lower
than the selected heatsealing temperature.
Controllers manufactured as of June 2006:
The maximum selectable preheat temperature is
limited by the rotary coding switch (alloy/range)
and/or the PC visualization software.
The preheat function can be deactivated by
entering 0°C.
Controllers manufactured
up to May 2006:
0°C…set point
Controllers manufactured
as of June 2006:
0, 40°C…maximum tem-
perature
!