Technical data
Type of construction
Controller:
Housing for installation in the electrical cabinet
Snaps onto a standard top hat rail (DIN TS35 rail, 35mm)
acc. to DIN EN 50022
Dimensions: 90 x 75mm; height: 135mm (incl. terminals)
Terminal:
Housing for installation in the electrical cabinet
Dimensions (W x H): 96 x 48mm; depth: 55mm (excl. connector)
Line voltage
Controllers manufactured as of June 2006:
115VAC version: 110VAC -15%…10% (equivalent to 94…132VAC)
230VAC version: 220VAC -15%…10% (equivalent to 187…264VAC)
400VAC version: 380VAC -15%…10% (equivalent to 323…456VAC)
Controllers manufactured between January 2004 and May 2006:
115VAC version: 115VAC -15%…10% (equivalent to 98…132VAC)
230VAC version: 230VAC -15%…10% (equivalent to 196…264VAC)
400VAC version: 400VAC -15%…10% (equivalent to 340…456VAC)
Controllers manufactured up to December 2003:
115VAC, 230VAC or 400VAC, tolerance: +10% / -15%
depending on device version (
section 14 "How to order" on page 61)
Line frequency
47…63Hz, automatic adjustment to frequencies in this range
Heatsealing band
type and temperature
range
Controllers manufactured as of June 2006:
The temperature range and temperature coefficient settings can also be specified
in the ROPEX visualization software (
section 11.19 "Diagnostic interface / vis-
ualization software (as of June 2006)" on page 51) in addition to using the rotary
coding switch (see below):
Temperature range:
200°C, 300°C, 400°C or 500°C
Temperature coefficient: 400…4000ppm (variable setting range)
Five different ranges can be set on the controller with the rotary coding switch:
Temperature coefficient 1100ppm, 0…300°C (e.g. Alloy A20), default
Temperature coefficient 780ppm, 0…300°C (e.g. Alloy L)
Temperature coefficient 1100ppm, 0…500°C (e.g. Alloy A20)
Temperature coefficient 780ppm, 0…500°C (e.g. Alloy L)
Temperature coefficient 3500ppm, 0…300°C (e.g. LEX3500)
Controllers manufactured up to May 2006:
Default value 300°C, Alloy A20
The temperature range and alloy can be selected with MOD 37.
Analog output
(actual value)
Terminals 17+18
0…10VDC, I
max
= 5mA
Equivalent to 0…300°C or 0…500°C
Accuracy: ±1% plus 50mV
Digital logic levels
Terminals 5+7
LOW (0V): 0…2VDC, electrically isolated
HIGH (24VDC): 12…30V DC (max. current input 6mA)
Reverse polarity-protected