Installation
Page 16
RES-408
Version 1
T-400 or T-408-1 terminal
9
Installation
See also section 1 "General information" on page 3.
Installation and startup may only be performed by technically trained, skilled persons who are
familiar with the associated risks and warranty provisions.
9.1
Installation procedure
Proceed as follows to install the RES-408 RESISTRON temperature controller:
1. Switch off the line voltage and verify that all circuits are deenergized.
2. The supply voltage specified on the nameplate of the RESISTRON temperature controller must be identical to
the line voltage that is present in the plant or machine. The line frequency is automatically detected by the tem-
perature controller in the range from 47Hz to 63Hz.
3. Install the RESISTRON temperature controller in the electrical cabinet on a standard top hat rail (DIN TS35 rail
according to DIN EN 50022). If several controllers are installed on one top hat rail, the minimum clearance
specified in section 6 "Technical data" on page 12 must be allowed between them.
4. Install the terminal in the front panel cutout. It is fastened by means of four clips which snap onto the side of
the terminal housing.
5. Connect the controller and terminal together with the cable provided for this purpose.
Controllers manufactured up to May 2006 are only allowed to be operated with a T-400 terminal.
Controllers manufactured as of June 2006 can only be operated with a T-408-1. Malfunctions or
damage may otherwise occur (
section 7 "Controller/terminal compatibility" on page 13).
6. Wire the system in accordance with the instructions in section 9.3 "Power supply" on page 19 and the ROPEX
Application Report. The information provided in section 9.2 "Installation steps" on page 18 must be heeded
additionally.