Startup and operation
RES-430
Page 17
9.1.3
Rear view of the terminal
9.2
General controller configuration
The possible controller configurations are explained in
the following sections. Proceed as described in
section 9.7.1 "Initial startup" on page 25 to start up the
controller for the first time.
The menu step numbers indicated in the
following are valid as of SW revision 007.
Please refer to the reference table in section 10.4
"Menu structure" on page 31 for information about
the numbers used for older controller versions.
9.2.1
Setting the language
The menu language can be changed on the controller
without interrupting operation. It is set with step 201 in
the Configuration menu:
The following settings are possible:
English, German, Italian
The language which is selected in this menu
remains set even if the factory settings are
restored (step 202 in the Configuration menu).
9.2.2
Restoring the factory settings
The internal controller settings can be reset to the
factory settings with step 202 in the Configuration
menu. Only the language setting (step 201 in the
Configuration menu) remains unchanged.
Please refer to section 11 "Factory settings" on
page 46 for more information about the factory settings.
If the controller settings are unknown when it
is started up for the first time, the factory
settings must be restored in order to prevent
malfunctions.
9.2.3
Configuration of the alloy
(temperature coefficient)
The heatsealing band alloy and the corresponding
temperature coefficient are set with steps 203 and 204
in the Configuration menu:
You can select preset values for the alloy (or the
temperature coefficient) with step 203:
1.
Temperature coefficient 780ppm
(e.g. Alloy-L)
2.
Temperature coefficient 1100ppm
(•)
(e.g. Alloy-20)
3.
Temperature coefficient 1400ppm
(e.g. ROPEX CIRUS system)
4.
Temperature coefficient 1700ppm
(e.g. ROPEX CIRUS system)
5.
Temperature coefficient 3500ppm
(e.g. NOREX)
6.
"Variable" temperature coefficient
Additional settings with step 204.
The temperature coefficient can be individually set
with step 204 for your particular heatsealing band in
the range from 400 to 4000 ppm.
Nameplate
Mounting clamps
Connecting cables
Mounting clamps
!
!
(•) Factory setting
!