57
Rhino RD180
1. Set thro le posi on to Idle.
2. Start the engine.
3. Keep engine speed in Idle.
4. Set purging switch to posi on.
5. Air from the compressor (6) is passed through the drier (5) and stored in
the primary tank (7).
6. When the purging switch is in operate condi on, air from the primary tank
is sent to the secondary tank (3).
7. A sequen al mer (9) operates the solenoid valves (4) at a preset me of
25 seconds to spray compressed air to the filters (1) via tubes (2) directly
above them.
8. A pneuma c manifold (8) controls the func ons of the system.
MACHINE OPERATION
CLEANING THE DUST FILTERS
The machine is equipped with nine dust filters to filter out fine dust during
sweeping opera on. The dust filters are automa cally cleaned by a
pneuma c purging system.
The below procedure explains the purging opera on:
1
2
3
4
5
1. Dust Filter
2. Purging Pipe
3. Secondary Air Tank
4. Solenoid Valve
5. Air Drier
6. Air Compressor
7. Primary Air Tank
8. Pneuma c Manifold
9. Timer
6
7
8
9
Содержание Rhino RD180
Страница 2: ...2 Rhino RD180...
Страница 4: ...4 Rhino RD180 INTRODUCTION...
Страница 7: ...7 Rhino RD180 TECHNICAL SPECIFICATION...
Страница 10: ...10 Rhino RD180 SAFETY INSTRUCTIONS...
Страница 17: ...17 Rhino RD180 KNOW YOUR MACHINE...
Страница 24: ...24 Rhino RD180 WORKING PRINCIPLE...
Страница 26: ...26 Rhino RD180 INITIAL SET UP...
Страница 29: ...29 Rhino RD180 CONTROLS...
Страница 45: ...45 Rhino RD180 MACHINE OPERATION...
Страница 58: ...58 Rhino RD180 MAINTENANCE...
Страница 80: ...80 Rhino RD180 TROUBLESHOOTING...
Страница 84: ...84 Rhino RD180 DO S DON TS...
Страница 86: ...86 Rhino RD180 OPERATOR NOTES...
Страница 87: ...87 Rhino RD180...