Appendix 1
Electrical, Mechanical and Thermal Characteristics
Standard Test Conditions (irradiance 1000 W/m
2
,
cell temperature 25 °C, spectrum AM1.5)
Acronym
Unit
3x8/110W/
RR33/B/DS
3x10/135W/
RR33/B/DS
3x12/160W/
RR33/B/DS
Nominal Power
P
max
(W)
110
135
160
Power Tolerance
0…+5 W
MPP Voltage
V
max
(V)
12.8
15.8
19.0
MPP Current
I
max
(A)
8.57
8.54
8.44
Open Circuit Voltage
V
oc
(V)
15.9
19.9
23.9
Short Circuit Current
I
sc
(A)
9.11
9.04
9.00
Normal Operating Conditions (irradiance 800 W/m
2
,
cell temperature 20 °C, spectrum AM1.5)
Nominal Power
P
max
(W)
80.8
99.2
116.8
MPP Voltage
V
mpp
(V)
11.9
14.7
17.41
MPP Current
I
max
(A)
6.78
6.75
6.71
Open Circuit Voltage
V
oc
(V)
14.7
18.4
21.87
Short Circuit Current
I
sc
(A)
7.24
7.19
7.20
Current and voltage tolerances ± 3%
Mechanical Characteristics
Design load front (Pa) and safety factor for mechanical load ym
1600; 1.5
Design load back (Pa) and safety factor for mechanical load ym
1600; 1.5
Material Group (MG) 1,2 according to IEC 60664-1
3
Pollution Degree (PD) according to IEC 60664-1
2