NEXUS CALL SYSTEM
by Rondish
P23
2.2 Configuring a Repeater Network
Connect the ZP-01(M) into the Nexus controller and configure the network settings (refer to Section
3.6.4). The repeater units ZP-01(S) installed around the facility must match the Network ID and Frequency
Channel selected for the Master. When you have configured the Master unit, but have not yet
programmed a network, the Home Screen will show the network as OFF.
As repeaters are added to the network, the Home Screen will display how many are included within the
network, and whether they are currently active. In the example below there are five repeaters in Nexus
memory, but only two are currently detected.
To program each ZP-01(S), you must set several parameters, each of which should be consistent with
what you have set on the ZP-01(M) master unit (Section 3.6.4).
1.
Set Network ID
2.
Set Frequency Channel
3.
Set Target Address
4.
Set Data Rate
5.
Set Repeater Address
To enter programming on a ZP-01(S), press and hold the T-SW button on back until the Tx/Rx
LED on the
front panel flashes and remains on. To enter a digit, use a screwdriver to select a number using the
Содержание Nexus Call System