Ronch Ronch Weld Series Скачать руководство пользователя страница 8

 

6. INSTALLATION & ADJUSTMENT 

 

Note: Please follow steps in strictly accordance with installation! 

Electrical connection operation must be shut after power distribution box power switch! 
The equipment protection level is IP23. Do not use it in the rain! 
 

 6.1. Installation 

 

(1)

 

Each machine is equipped with a power cable should be based on the input voltage welding 
power cable connected to the appropriate position, not to pick the wrong voltage. 

(2)

 

With the corresponding input power supply terminal or socket good contact and prevent 
oxidation. 

(3)

 

With a multi meter measure the input voltage is within the fluctuation range. 

(4)

 

To clamp the with welding front panel connector into the jack at the bottom of the cathode, 
clockwise tighten. 

(5)

 

To clamp the cable plug into the front panel below the negative welding socket, tighten 
clockwise. 

(6)

 

The power ground is well grounded. 

 
Above (4) and (5) for the DC reverse method. Operator also on the base metal and welding rod to 
choose DCSP method. In general, the basic electrode reverse method is recommended (ie, 
connected to the positive electrode), acid electrode makes special provisions. 
 

 6.2. OPERATION 

 

(1)

 

According to the above method to install is correct, turn the power switch, so that the power 
switch is “ON” position, then the power indicator light, the fan comes on, the device work 
properly. 

(2)

 

Note the polarity of wiring, the general DC welding wire in two ways: positive and reverse 
polarity connection method. Positive Connection: Welding clamp then negative, then positive, 
then positive work piece; reverse law contrary. Selected according to the technical 
requirements of welding the appropriate connection, is you choose incorrectly will result in 
arc instability and spatter large adhesion and other phenomena, such cases can be quickly 
reversed to joints. 

(3)

 

If the work piece distance from the welding machine, the second line (electrode holder and 
ground) is longer, so choose the appropriate conductor cross-sectional area should be larger 
to reduce cable voltage drop. 

(4)

 

According to the standard, model pre-set welding electrode current, electrode clip will be 
good, you can use short-circuit arc welding, welding parameters can refer to 6.3. 

 
 
 
 

Содержание Ronch Weld Series

Страница 1: ...SERIES 200MAX STICK TIG ...

Страница 2: ...NCIPLE DRAWING 5 4 PARAMETERS 6 5 OPERATION CONTROL CONNECTORS 7 6 INSTALLATION ADJUSTMENT 8 6 1 Installation 8 6 2 OPERATION 8 6 3 WELDING TABLE 9 7 OPERATION NOTICES 10 7 1 Installation 10 7 2 Safety 10 8 MAINTENANCE 11 9 TROUBLESHOOTING SERVICE 12 ...

Страница 3: ... can be dangerous Welding may produce fumes and gases hazardous to health Avoid breathing these fumes and gases When welding keep your head out the fume Using enough ventilation and or exhaust at the arc to keep fumes and gases away from the breathing zone Welding sparks can cause fire or explosion Remove fire hazards from the welding area If this is not possible cover them to prevent the welding ...

Страница 4: ...e are also some automatic protection functions for under voltage over current over heat etc inside the welders when the problems listed before occurred the alarm on the front panel is light and at the same time the output current will be cut off It can self protect and prolong the using life and greatly improved the reliability of the welders ARC series can be ignited easily also with little splas...

Страница 5: ...5 3 ELECTRICAL PRINCIPLE DRAWING PO W ER PC B O n O ff Sw i tc h 2 2 0 V A C Front Panel ...

Страница 6: ...nt A 47 MMA 32 TIG Duty Cycle 40 10min 60 200A 100 155A No Load Voltage V 61 Welding Current Range A 10 200 Efficiency 85 Power Factor 0 70 Net Weight Kg 6 2 Protection Class IP23 Insulation Class H Dimensions mm 365 150 240 Electrode Diameter Φ1 6 Φ5 0 Electrode Type 6013 7018 etc Note The above parameters are subject to change with the improvement of machines ...

Страница 7: ...ut current size 4 Power indicator power indicator power on light on 5 Alarm light alarm indicator lights that occurred over voltage over current or overheating inside the machine is protected 6 Current digital display 7 Power switch control power through and break 8 Fan Help plant cooling 9 Power Access client access to cable 10 Conversion switch choose left LIFT TIG choose right MMA ...

Страница 8: ...al the basic electrode reverse method is recommended ie connected to the positive electrode acid electrode makes special provisions 6 2 OPERATION 1 According to the above method to install is correct turn the power switch so that the power switch is ON position then the power indicator light the fan comes on the device work properly 2 Note the polarity of wiring the general DC welding wire in two ...

Страница 9: ... steel other materials please refer to related information Electrode diameter mm Recommended welding current A Recommended welding voltage V 1 0 20 60 20 8 22 4 1 6 44 84 21 76 23 36 2 0 60 100 22 4 24 2 5 80 120 23 2 24 8 3 2 108 148 23 32 24 92 4 0 140 180 24 6 27 2 ...

Страница 10: ...rmal operation of welding machine extending welder life 2 Prohibit the overload By welding machine operators should ensure that the duty cycle to allow use of welding see technical data table keeping the welding current within the normal range if the current overload will shorten the life of welding machine welding machine and may even burn 3 Prohibits the over voltage Supply voltage listed in the...

Страница 11: ...as mot to hurt or cause damage to the machine 3 Regularly with a clean dry compressed air to dust the machine compressed air pressure should be at reasonable levels in order to avoid damage to the welding of small components inside Dust the machine works well no dust under normal circumstances except in exceptional circumstances 4 Avoid water or water vapor into the welding machine inside if there...

Страница 12: ...welding current control current big sometimes small The current potential is damaged should be replaced Bad connections such as plug in to be checked Power indicator light shows the normal fan rotating normal no welding output Check all connectors inside the machine if there is bad A circuit output connections or bad the alarm indicator light 1 That access to protected status because of overheatin...

Страница 13: ...13 200MAX STICK TIG ...

Отзывы: