7. OPERATION NOTICES 

 

 7.1. Installation 

 
(1)

 

Welding environmental temperature should be between -10

 to 40

(2)

 

Welding should be done in relatively dry environments, the air humidity of not more than 
90%. 

(3)

 

To avoid areas containing dust or corrosive gas welding operation environment. 

(4)

 

To avoid sunlight or rain, welding, do not le water or rain water infiltrated the welding 
machine. 

(5)

 

To avoid the strong air flow environment for gas welding operations. 

 

 7.2. Safety 

 
Welding machine has been installed in over-voltage, over current and over temperature 
protection circuit, when the grid voltage, output current and the internal temperature exceeds the 
set temperature, the welding machine will automatically stop working; but excessive use will 
result in welding damage, so you need to note the following: 
(1)

 

To ensure good ventilation! 

The welder at work have a greater current flow through the cooling of natural ventilation van not 
meet the requirements of welding, it is equipped with cooling fans to help the welder. Before 
using, please check the vents to make sure it has not been blocked or covered the distance 
between the object and the surrounding welding should not be less than 0.3 meters, welding 
machines should have been so good ventilation, to ensure the normal operation of welding 
machine extending welder life. 
(2)

 

Prohibit the overload! 

By welding machine operators should ensure that the duty cycle to allow use of welding (see 
technical data table), keeping the welding current within the normal range, if the current overload 
will shorten the life of welding machine welding machine and may even burn. 
(3)

 

Prohibits the over-voltage! 

Supply voltage listed in the “Technical Data Sheet”, the general case, the welding voltage within 
the circuit will automatically compensate to ensure that the welding current in the permitted 
range. If the voltage exceeds the allowable value, will damage the welder, the user should be fully 
aware of this situation, take appropriate preventive measures. 
(4)

 

After each welding machine comes with grounding screw, and marked with ground markers. 
Before use, use a larger than 2.5mm cable, in the welding chassis ground to discharge any 
static electricity or to prevent leakage accidents. 

(5)

 

If the welding work over the standard loading time, the welding machine may suddenly stop 
working into the protected status, which means that the load beyond the standard rate of 
welding, excessive heat triggered a temperature control switch, the welding machine to stop 
working, while front panel alarm indicator lights up. In this case, you do not unplug the power 
plug, to maintain the cooling fan rotation. The red light goes out, the temperature dropped to 
a reasonable extent, and then you can restart welding. 

 

Содержание Ronch Weld Series

Страница 1: ...SERIES 200MAX STICK TIG ...

Страница 2: ...NCIPLE DRAWING 5 4 PARAMETERS 6 5 OPERATION CONTROL CONNECTORS 7 6 INSTALLATION ADJUSTMENT 8 6 1 Installation 8 6 2 OPERATION 8 6 3 WELDING TABLE 9 7 OPERATION NOTICES 10 7 1 Installation 10 7 2 Safety 10 8 MAINTENANCE 11 9 TROUBLESHOOTING SERVICE 12 ...

Страница 3: ... can be dangerous Welding may produce fumes and gases hazardous to health Avoid breathing these fumes and gases When welding keep your head out the fume Using enough ventilation and or exhaust at the arc to keep fumes and gases away from the breathing zone Welding sparks can cause fire or explosion Remove fire hazards from the welding area If this is not possible cover them to prevent the welding ...

Страница 4: ...e are also some automatic protection functions for under voltage over current over heat etc inside the welders when the problems listed before occurred the alarm on the front panel is light and at the same time the output current will be cut off It can self protect and prolong the using life and greatly improved the reliability of the welders ARC series can be ignited easily also with little splas...

Страница 5: ...5 3 ELECTRICAL PRINCIPLE DRAWING PO W ER PC B O n O ff Sw i tc h 2 2 0 V A C Front Panel ...

Страница 6: ...nt A 47 MMA 32 TIG Duty Cycle 40 10min 60 200A 100 155A No Load Voltage V 61 Welding Current Range A 10 200 Efficiency 85 Power Factor 0 70 Net Weight Kg 6 2 Protection Class IP23 Insulation Class H Dimensions mm 365 150 240 Electrode Diameter Φ1 6 Φ5 0 Electrode Type 6013 7018 etc Note The above parameters are subject to change with the improvement of machines ...

Страница 7: ...ut current size 4 Power indicator power indicator power on light on 5 Alarm light alarm indicator lights that occurred over voltage over current or overheating inside the machine is protected 6 Current digital display 7 Power switch control power through and break 8 Fan Help plant cooling 9 Power Access client access to cable 10 Conversion switch choose left LIFT TIG choose right MMA ...

Страница 8: ...al the basic electrode reverse method is recommended ie connected to the positive electrode acid electrode makes special provisions 6 2 OPERATION 1 According to the above method to install is correct turn the power switch so that the power switch is ON position then the power indicator light the fan comes on the device work properly 2 Note the polarity of wiring the general DC welding wire in two ...

Страница 9: ... steel other materials please refer to related information Electrode diameter mm Recommended welding current A Recommended welding voltage V 1 0 20 60 20 8 22 4 1 6 44 84 21 76 23 36 2 0 60 100 22 4 24 2 5 80 120 23 2 24 8 3 2 108 148 23 32 24 92 4 0 140 180 24 6 27 2 ...

Страница 10: ...rmal operation of welding machine extending welder life 2 Prohibit the overload By welding machine operators should ensure that the duty cycle to allow use of welding see technical data table keeping the welding current within the normal range if the current overload will shorten the life of welding machine welding machine and may even burn 3 Prohibits the over voltage Supply voltage listed in the...

Страница 11: ...as mot to hurt or cause damage to the machine 3 Regularly with a clean dry compressed air to dust the machine compressed air pressure should be at reasonable levels in order to avoid damage to the welding of small components inside Dust the machine works well no dust under normal circumstances except in exceptional circumstances 4 Avoid water or water vapor into the welding machine inside if there...

Страница 12: ...welding current control current big sometimes small The current potential is damaged should be replaced Bad connections such as plug in to be checked Power indicator light shows the normal fan rotating normal no welding output Check all connectors inside the machine if there is bad A circuit output connections or bad the alarm indicator light 1 That access to protected status because of overheatin...

Страница 13: ...13 200MAX STICK TIG ...

Отзывы: