background image

For parts or assistance, call Customer Service at 1-800-265-7241

Specifications and Safety

2

DESCRIPTION

This Submersible Sump Pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-type
power cord. Shaded-pole motor is oil filled and sealed
for cooler running. Sleeve bearings on motor shaft never
need lubrication. Features automatic reset thermal pro-
tection. Not designed for use as a swimming pool 
drainer.

SPECIFICATIONS

Power supply required ...........................115V, 60 HZ.
Liquid Temp. Range ................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ....15 Amps
Discharge .........................1-1/4" FNPT / 1-1/2" MNPT

NOTICE:

Do not reduce size of discharge pipe or

hose below 1-1/4” diameter. If discharge is too
small, pump will overheat and fail prematurely.
This pump is designed for use in a residential sump
only. Pump water only with this pump.

NOTICE:

This unit is not designed as a waterfall or foun-

tain pump, or for applications involving salt water or
brine! Use with waterfalls, fountains, salt water or brine
will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.

NOTICE: Read this Owner’s Manual for installation,
operation, and safety information.

PERFORMANCE

ELECTRICAL & SWITCH SPECIFICATIONS

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give
many years of trouble-free service when correctly
installed, maintained, and used. However, unusual
circumstances (interruption of power to the pump,
dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from func-
tioning normally. To prevent possible water damage
due to flooding, consult your retailer about a sec-
ondary AC sump pump, a DC backup sump pump,
and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common
sump pump problems and remedies. For more infor-
mation, call customer service at 1-800-265-7241.
1. Know the pump application, limitations, and

potential hazards.

2.

Do not use in water with fish present. If any oil
leaks out of the motor it can kill fish.

3. Disconnect power before servicing.
4. Release all pressure within system before servic-

ing any component.

5. Drain all water from system before servicing.
6. Secure discharge line before starting pump. An

unsecured discharge line will whip, possibly
causing personal injury and/or property damage.

7. Check hoses for weak or worn condition before

each use, making certain that all connections are
secure.

8. Periodically inspect sump, pump and system

components. Keep free of debris and foreign
objects. Perform routine maintenance as
required. 

9. Provide means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

10. Personal Safety:

a. Wear safety glasses at all times when working

with pumps.

b. Keep work area clean, uncluttered and prop-

erly lighted – replace all unused tools and
equipment.

c. Keep visitors at a safe distance from work

area.

d. Make workshop child-proof – with padlocks,

master switches, and by removing starter
keys.

11. When wiring an electrically driven pump, follow

all electrical and safety codes that apply.

12.

This equipment is only for use on 115 volts 
(single phase) and is equipped with an
approved 3-conductor cord and 3-prong,
grounding-type plug.

GPH (LPH) AT TOTAL FEET (M) OF LIFT

5

10

15

Series

HP

(1.5m)

(3m)

(4.6m)

CAPACITY GALLONS(L)/HOUR

20035026 

1/4

2280

1620

660

18 Ft.

( 8 631)

(6 132)

(2 498)

(5.5M)

20035027 

1/2

3200

2700

2000

24 Ft.

(12 113) (10 220)

(7 571)

(7.3M)

20035028 

1/2

3200

2700

2000

24 Ft.

(12 113) (10 220)

(7 571)

(7.3M)

No flow 

at height

shown

below

Individual

Motor

Branch

*Switch Setting

Full Load

Circuit

in inches (mm)

Series

HP

Amps

Req.(Amps)

On

Off

20035026

1/4

8.8

15

12

1

/

2

"(318) 4

1

/

2

"(114)

20035027

1/2

5.5

15

14"(356)

6"(152)

20035028

1/2

5.5

15

8"(203)

3

1

/

2

"(89)

Содержание 20035026

Страница 1: ...OWNER S MANUAL Submersible Sump Pumps Installation Operation Parts For further operating installation or maintenance assistance Call 1 800 265 7241 RON875 5 21 10 20035026 20035027 20035028 ...

Страница 2: ...g Chart in this manual for information about common sump pump problems and remedies For more infor mation call customer service at 1 800 265 7241 1 Know the pump application limitations and potential hazards 2 Do not use in water with fish present If any oil leaks out of the motor it can kill fish 3 Disconnect power before servicing 4 Release all pressure within system before servic ing any compon...

Страница 3: ...ces Clean sump pit of small stones and gravel which could clog pump Keep pump inlet screen clear NOTICE Do not use ordinary pipe joint com pound on plastic pipe Pipe joint compound can attack plastics 4 Install discharge plumbing Use rigid plastic pipe and wrap threads with TeflonTM tape Screw pipe into pump hand tight plus 1 1 2 turns Risk of flooding If a flexible dis charge hose is used make su...

Страница 4: ...impeller very low head or lift or a plugged or frozen discharge pipe etc could cause cycling 3 Pump will not remove all water If operating a pump manually and suddenly no water comes out of the discharge hose shut off the unit immediately The water level is probably very low and the unit has broken prime Risk of electric shock Before attempting to check why unit has stopped oper ating disconnect p...

Страница 5: ... 2 Cord Clamp Screw 1 U30 955PS U30 955PS U30 955PS 3 Float Switch Cord Clamp 1 CC0030 13 CC0030 13 4A Vertical Float Switch Assembly 1 FPS17 66 4B Tethered Float Switch Assembly 1 FP18 15BD FP18 15BD 5 Motor 1 6 Volute Upper 1 PS1 32P PS1 31P PS1 31P 7 Screw 8 32x5 8 Phillips Pan Head 4 U30 912PS U30 912PS U30 912PS 8 Impeller 1 RP0000917 RP0000911A RP0000911A 9 Volute Lower 1 PS1 30P PS1 30P PS1...

Страница 6: ...eplace float switch Restricted discharge Remove pump and clean pump and piping obstacle or ice in piping Float obstructed Remove obstruction Restricted intake screen Remove the pump and clean the intake screen and the impeller Pump operates but Low line voltage If voltage under recommended minimum check size of wiring delivers little or no water from main switch on property If OK contact power com...

Страница 7: ...azard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Warranty Period Submersible Sump Pump models 20035027 20035028 3 Years General Terms and Co...

Страница 8: ...8 ...

Страница 9: ...UR Pompes submersibles pour puisard Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 265 7241 RON875 21 5 10 20035026 20035027 20035028 ...

Страница 10: ...el pour plus de renseignements concer nant les problèmes courants des pompes de puisard et leurs remèdes Pour de plus amples renseignements s adresser au détaillant ou appeler le service à la clien tèle en composant le 1 800 265 7241 1 Avant tout il faut connaître les applications de la pompe ces limites et les dangers potentiels que présente son utilisation 2 Ne pas utiliser pour pomper de l eau ...

Страница 11: ...r puisse avoir le plus grand dégagement possible 3 Il ne faut pas poser la pompe sur une surface en argile en terre ou sablonneuse Enlever les petites pierres et le gravier du puisard qui risqueraient de boucher la pompe La crépine d admission d eau de la pompe doit toujours être dégagée NOTA Ne pas utiliser de pâte à joint ordinaire pour tuyaux filetés sur les tuyaux en plastique car cette pâte a...

Страница 12: ...ermit tent 3 La pompe n aspirera pas toute l eau Si on fait fonc tionner la pompe manuellement et que brusque ment l eau ne coule plus par son tuyau de refoule ment arrêter immédiatement la pompe Le niveau de l eau est probablement très bas et la pompe s est désamorcée Risque de chocs électriques Avant de vérifier pourquoi cette pompe a cessé de fonctionner interrompre le courant parvenant à la po...

Страница 13: ...54 TSU PS117 54 TSU PS117 54 TSU 2 Vis du collier de cordon 1 U30 955PS U30 955PS U30 955PS 3 Collier du cordon de l interrupteur à flotteur 1 CC0030 13 CC0030 13 4A Interrupteur à flotteur vertical 1 FPS17 66 4B Interrupteur à flotteur à cordon 1 FP18 15BD FP18 15BD 5 Moteur 1 6 Volute supérieure 1 PS1 32P PS1 31P PS1 31P 7 Vis à tête cylindrique à empreinte cruciforme n 8 32 x 5 8 de pouce 4 U30...

Страница 14: ...otteur défectueux La pompe refuse de Interrupteur du flotteur Remplacer l interrupteur du flotteur s arrêter défectueux Diminution du refoulement Retirer la pompe et nettoyer la pompe et la canalisation obstruction ou glace dans la tuyauterie Obstruction du flotteur Dégager le mouvement du flotteur La crépine d aspiration Retirer la pompe et nettoyer la crépine d aspiration ainsi est obstruée que ...

Страница 15: ...as de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la réglementation locale Exceptions à la garantie limitée de douze 12 mois Produit Période de garantie Pompe de puisard submersible modèles 2003...

Страница 16: ...8 ...

Отзывы: