SCULPTURES ANGLED WALK-IN TROUBLE SHOOTING GUIDE.
Problem
Solution
LEAKING:
1.
Check the tray has been sealed correctly prior to the installation of the enclosure Step 1:
2.
Check their is a bead of bathroom sealant the width of the wall profiles has been placed between the
tiled wall and tray top where the wall profiles meet the tiled walls Step 2, line 3. Step 6, line 3 if fitting
in conjunction with a side panel:
3.
Check that the base of the enclosure is sealed to the tray top/wetroom floor from the outside only Step
5, line 3:
4.
Check to see if the wall profiles have been sealed vertically inside and outside where they meet the
tiled wall only Step 5, line 4:
5.
Check that the base of the enclosure hasn’t been sealed to the tray top/wetroom floor on the inside of
the cubicle:
6.
If fitting on to a tray you must ensure that the glass panels are sitting inside the groove of the tray (The
enclosure must be fitted on a Roman Sculptures tray i.e. failure to do so will result in the enclosure
leaking):
Important: This enclosure should be water tested conforming to BS EN 14428 2004
ENCLOSURE
1.
Check to see that the enclosure has been fitted onto tiled surface or a similar sealed surface.
ALIGNMENT:
2.
Check that the the wall profiles have been fitted directly in line with the groove in the
tray Step2, line 1. Step 6, line 1 if fitting in conjunction with a side panel:
3.
Check that the wall profiles have been fitted completely vertical (the bubble must be in the centre of
the two lines on a spirit level) Step 2, line 1. Step 6, line 1 if fitting in conjunction with a side panel.
4.
Ensure the glass panels are sitting inside the groove of the tray and are completely vertical:
5.
Ensure the Enclosure is completely vertical and level (the bubble must be in the centre of the two lines
on a spirit level):
6.
Check the tray is completely level, this is very important as this will have knock on effect on the
aesthetics of the product Step 1:
GLASS PANELS
1.
Check that all the allen bolts on the glass to glass brackets have been tightened to 10Nm with a torque
MOVING:
wrench.
2.
Check that the base of the enclosure has been sealed to the tray/wetroom floor Step 5, line 3.
INTEGRATED WATER
DELIVERY DOESN’T
FIT THE GLASS PANEL:
1.
Check the glass is the correct way around:
Important
The walls which the enclosure is to be fitted to must be vertical with no more than 5mm deviation. A maximum of
5mm adjustment is provided within the enclosure to take account for untrue walls.
SNCW-SNWCG:CQB