ROMAN SNWC Скачать руководство пользователя страница 2

IMPORTANT PRE-INSTALLATION CHECKS

1. Check the tray is level, on all sides (the bubble should be in the centre of the two lines on the spirit level).
2. Stand in the tray and check for no adverse movement.
3. The walls should be tiled and grouted up to the tray.
4. The tiles and the tray should be sealed, using a good quality bathroom sealant.

Spray the seal and joints with the shower head and check for leaks when the silicon has cured.

Check the plumbing for leaks.

Do not plasterboard over the tray.

Do not grout the tiles when the enclosure has been fitted as the grout may discolour the aluminium profiles.

Make sure the tray is installed as per manufacturer’s instructions.

When all of the above has been completed please proceed to Step 2.

Important:

If you are fitting in conjunction with the integrated water delivery, you must refer to the valve fitting instructions

before installing your enclosure or tray.

Under floor preparation will be required to accommodate the valve prior to the installation of the enclosure, tray or final
construction of the wet-room.

Step 1 - Checking & Sealing the tray

Please make sure the purchaser/end user completes and returns the Guarantee card which is enclosed with
this product or registers on line at

www.roman-showers.com/register_guarantee.htm

. Failure to validate the

Roman Truelife Guarantee will mean only the 1 Year Statutory Guarantee will apply.

Truelife Consumer
Guarantee

BEFORE COMMENCING INSTALLATION
PLEASE ENSURE THAT THE SITE AND
TRAY REQUIREMENTS HAVE BEEN
COMPLETED.

The installer becomes liable for any call
out and/or rectification costs if the problem
found is a result of an attempted
installation on an unacceptable site.

SNCW-SNWCG:CQB

14/5/10  11:35  Page 2

Содержание SNWC

Страница 1: ... p t u r e s Angled Walk in Instruction Manual IMPORTANT I Please ensure the consumer guarantee card enclosed with this product is completed and returned to Roman please ensure the end user retains this manual I Please read all instructions carefully before attempting installation I Handle the product with care to avoid damage to the product finish I Check for hidden electrical cables and water pi...

Страница 2: ...re fitting in conjunction with the integrated water delivery you must refer to the valve fitting instructions before installing your enclosure or tray Under floor preparation will be required to accommodate the valve prior to the installation of the enclosure tray or final construction of the wet room Step 1 Checking Sealing the tray Please make sure the purchaser end user completes and returns th...

Страница 3: ...th the glass groove in the tray the outside edge of the wall profile will be approximately 15mm in from the outside edge of the tray 2 Drill the holes using 6mm masonry drill bit not supplied Push the wall plugs supplied into the drilled holes 3 Apply a bead of silicon the width of the wall profile at the bottom where it meets the tiled wall Important failure to carry out this procedure can result...

Страница 4: ...ve the allen bolts and spacers from the back plates on both 45 degree brackets fit the 45 degree brackets to the first panel and the angled glass panel in order as shown above If fitting with the integrated water delivery please ensure your glass panel is the correct way up when installing Once the 45 degree brackets have been assembled onto the first panel and angled panel the allen bolts must be...

Страница 5: ...ngled panel as shown above failure to do so will cause sealing problems in Step 5 3 Using the same procedure in line 1 fit the 90 brackets to the front panel and the return panel in order as shown above Once the 90 degree brackets have been assembled onto the front panel return panel the allen bolts must be tightened to 10Nm using a torque wrench Ensure the allen bolts face in towards the showerin...

Страница 6: ...f the wall profiles inside and outside vertically where they meet the tiled wall Very important Failure to follow the procedure in lines 2 4 may result in serious water damage and is not covered under the terms of the guarantee Ensure the sealant is less than 3mm thick this ensures that the sealant dries clear Please allow 24 hours for the bathroom sealant to fully cure prior to using the enclosur...

Страница 7: ...portant no sealant should be present between the wall profile and the tiled wall vertically prior to screw fixing 5 Using an allen key loosen the screws down the side of the wall profile by 3 turns 6 Position the flexible seal onto the end of the side panel Offer the side panel fully into the wall profile then tighten all the allen screws down the side of the wall profile using the supplied allen ...

Страница 8: ...lations on 01325 328034 No Description SNWC Qty SNWCG Qty 1 Glass Side Panel 1 2 Cover Trims 2 4 3 Wall Profiles 1 2 4 Top Caps 1 2 5 Return Panel 1 1 6 90º Degree Brackets 2 2 7 Front Glass Panel 1 1 8 45º Degree Brackets 4 4 9 Angled Glass Panel 1 1 10 First Glass Panel 1 1 SNCW SNWCG CQB 14 5 10 11 35 Page 8 ...

Страница 9: ...led surface or a similar sealed surface ALIGNMENT 2 Check that the the wall profiles have been fitted directly in line with the groove in the tray Step2 line 1 Step 6 line 1 if fitting in conjunction with a side panel 3 Check that the wall profiles have been fitted completely vertical the bubble must be in the centre of the two lines on a spirit level Step 2 line 1 Step 6 line 1 if fitting in conj...

Страница 10: ...assemblies and other moving parts from time to time It is strongly recommended that a quality silicone spray is used A list of Don ts 1 Don t use acidic based products which are unsuitable for cleaning enamel surfaces 2 Don t use Abrasive cleaners or cleaners containing bleach or solvents these products will adversely affect the finish of the aluminium profiles 3 Don t use scouring pads powder or ...

Страница 11: ...RHAM DL5 6YN ENGLAND UK www roman showers com GENERAL RECEPTION PHONE 44 0 1325 311318 FAX 44 0 1325 319889 CUSTOMER RELATIONS PHONE 44 0 1325 328034 FAX 44 0 1325 328031 SALES ENQUIRIES PHONE 44 0 1325 328033 FAX 44 0 1325 328027 SNCW SNWCG CQB 14 5 10 11 35 Page 12 ...

Отзывы: