background image

Manual No. 4801-5163  

Replacement Instructions 

Door Assembly PCB154 to PCB201 

 

Figure 8: New Door Assembly Installed 

Controller Setup: 

Once the replacement installation has been concluded, the controller will need to be setup to 
match the settings that were noted in a previous step. Refer to the 4801-5156 Controller Manual 
for more information involving setup of the controller. This manual can be downloaded from 

www.rollseal.net/

. The notes that were taken on the provided white label should all be the same 

during the setup. There will be several new parameters added and they should be set as 
designated on the pre-printed label. 
 
As was previously mentioned, there have been several program parameters added to this new 
door assembly and there will be values printed on these parameters that will allow for easy setup. 
There has been more capability added to the “P4” setting where the Warning Output can now be 
set to sense a fully open/fully closed status with P4=4 and P4=5 respectively. Refer to Figure 9 
for more information. 
 

Содержание SC-325

Страница 1: ...Manual No 4801 5163 Replacement Instructions Door Assembly PCB154 to PCB201 RollSeal SC 325 SC 650 Door Assembly Replacement Instructions RollSeal 1733 County Road 68 Bremen Alabama 35033 256 287 7000...

Страница 2: ...under Program Parameters on the control label There will also be a white label sent with the new door assembly that will allow the user to take note of the important parameters that will need to be se...

Страница 3: ...Manual No 4801 5163 Replacement Instructions Door Assembly PCB154 to PCB201 Figure 2 Old Door Assembly Figure 3 Harnesses to Detach...

Страница 4: ...removed Ensure that the hinge pin is pushed all the way in and is flush at the top Figure 4 Removing Door Assembly Replacing the KB Drive Harness In order to configure the new door assembly the harne...

Страница 5: ...wired Referring to the previously taken picture place the black wire terminals in their corresponding board location based on the title designation listed on the board Connect the two white connectors...

Страница 6: ...ww rollseal net The notes that were taken on the provided white label should all be the same during the setup There will be several new parameters added and they should be set as designated on the pre...

Страница 7: ...rlock 2 Passive Interlock 3 Freezer Mode No Interlock 4 Door Open Indication 5 Door Closed Indication P5 CMS On Time P6 CMS Off Time P7 Refresh Door Limits P10 Service Cycle Reset 0 No 1 Yes P11 Servi...