Problem
Cause
Remedy
Motor is not responding
Switch power supply is not
connected
Check power source and
connections.
Radio interference / Shielding
Ensure switch is positioned away
from metal objects and that
the antenna on motors are kept
straight and away from metal.
Receiver distance is too far from
switch
Move switch to a closer position.
Power failure
Check power supply to motor is
connected and active (non-battery
motors).
Incorrect motor wiring
Check motor wiring is connected
correctly (refer to motor
installation instructions).
Cannot set limits on a single
motor (multiple motors respond)
Transmitter has group control
function set and drives all the
paired motors together
Use an ARC remote to individually
adjust motor limits.
Use
P1
motor button to set other
motors in group into “Sleep” mode.
SYSTEM BEST PRACTICE - Provide
an extra 15 channel switch or
remote in you multi motor projects
to provide individual control for
each motor for programming/
configuration purposes.
Motor will not go down after
setting the top limit
Top limit was set using the down
and stop buttons
Reset the motor and begin
programming sequence again.
Remember that upper limit is to be
set using the up and stop and the
down limit is set using the down
and stop.
7
TROUBLE SHOOTING