4
| Automate
™
Programming Instructions | FT Tubular Motors
ROLLEASE ACMEDA
.
Crown
Magnetic
Ring
Bracket
Drive
Adapter
Retaining
Clip
Motor
Head
Step 1.
Cut roller tube to required length.
Please refer to Rollease Acmeda System Assembly Manual for full assembly instructions relevant to the
hardware system being used.
Step 2.
Ensure roller tube is clean and free from burrs.
Step 3.
Fit required crown, drive and bracket adapters.
Step 4.
Slide Motor into tube.
Insert by aligning key-way in crown and drive
wheel into the tube.
Step 5.
Mount motorized tube onto brackets.
Refer to Rollease Acmeda System Assembly
Manual for recommended crown, drive and
bracket adapter kits.
1
ASSEMBLY
For impact dectection to be functional, a 2
piece drive set must be used. Using a standard
1 piece drive will render the collision control
feature inoperable even if the feature is turned
on.
Tube must be close fitting with chosen crown
and drive adapters. A Hall effect sensor
embedded in the tube measures the magnetic
field change and detect the impact. Refer to
Rollease Acmeda System Assembly Manual
for recommended crown, drive and bracket
adapter kits.