background image

AUTOMATE

 

ARC TUBULAR FT MOTOR

433 MHZ 

BI-DIRECTIONAL

ELECTRONIC 

LIMIT

FAVORITE 

POSITION

FABRIC 

TENSION

ULTRA 

LOCK

IMPACT 

DETECTION

FEATURES:

Impact Detection (Zipscreen Only)

High Fabric tension torque

433 MHz Bi-Directional RF Communication

Electronic Limit

Favorite Position

Ideal for premium outdoor Zipscreen shade solution

One action to lock & un-lock shade

AUTOMATE | FT tubular AC motors combine the simple, intuitive features of ARC 
“Automate Radio Communication” with the higher lifting capacity of an AC motor for 
larger shade applications. Three alternate modes of operation include:

E-type for standard use

MANUAL FT Mode for use with conventional locking devices with fabric tensioning

AUTO FT Mode for use with Rollease Acmeda’s proprietary ULTRA LOCK providing
automatic fabric tensioning

Functional options in each operating mode include: IMPACT DETECTION and FAVORITE 
POSITION.

IMPACT DETECTION senses an obstacle in the blinds path during downward
movement and redirects the shade to protect the motor, hardware and fabric,
ensuring product longevity.

An intermediate setting allows for a customized FAVORITE POSITION to be preset.

AU

US

INS

TR. MT01-1145-0xx00x v1.15 JUL

Y 2019

Содержание AUTOMATE AU

Страница 1: ...pacity of an AC motor for larger shade applications Three alternate modes of operation include E type for standard use MANUAL FT Mode for use with conventional locking devices with fabric tensioning A...

Страница 2: ...S AND CHANNELS 11 6 1 Using motor P1 Button to add a new controller or channel 11 6 2 Using a pre existing controller to add or delete a controller or channel 11 7 FAVORITE POSITIONING 12 7 1 Set a fa...

Страница 3: ...e is compatible with end application Do not expose the motor to water or install in humid or damp environments Motor is to be installed in horizontal application only Do not drill into motor body The...

Страница 4: ...gning key way in crown and drive wheel into the tube Step 5 Mount motorized tube onto brackets Refer to Rollease Acmeda System Assembly Manual for recommended crown drive and bracket adapter kits 1 AS...

Страница 5: ...connecting or disconnecting this motor This connector must not be acces sible to the end user It shall be placed within a pelmet box or within a housing in accordance to AS NZS 60335 1 2011 or BS EN...

Страница 6: ...limit TENSION UNLOCK MODE 1 E Type DEFAULT MODE 2 FT MODE Automatic Lock MODE 3 FT MODE Manual Lock 2 62 x TUBE DIAMETER 2 62 x TUBE DIAMETER Inactive zone of impact detection Active zone of impact d...

Страница 7: ...UNCTIONS P1 Press Condition Function Achieved Visual Feedback Audible Feedback Function Described Short Press If limit is NOT set None No Action None No Action If limits are set Operational control of...

Страница 8: ...uring initial set up Hold P1 button on motor head To check travel direction of shade press UP or DOWN on controller Quick Press Step Long Press Continuous Travel To reverse shade direction hold both U...

Страница 9: ...s set refer to Section 10 to activate Fabric Tension Mode After setting limits motor will automatically exit from initial set up mode Move shade to the desired highest position by pressing the UP butt...

Страница 10: ...pressing the UP button To save upper limit hold UP and STOP To save lower limit hold DOWN and STOP Approx Approx Motor Response Motor Response Motor Response Motor Response 5 ADJUSTING LIMITS SEC SEC...

Страница 11: ...ntroller to remove it Hold P1 button on motor head Hold STOP on controller to add Motor keeps original limits Approx Approx Motor Response Motor Response Motor Response Motor Response Motor Response 6...

Страница 12: ...the desired position by pressing the UP or DOWN button on the controller Press P2 on controller Press STOP on controller Press STOP on controller Approx Motor Response Motor Response Motor Response Mo...

Страница 13: ...hen re power the motor The Impact Detection feature only works in the active zone during downward movement see Section 2 4 All three modes have this impact detection feature deactivated by default see...

Страница 14: ...s selected Note Motor must be in FT mode before switching between lock modes Press P2 on controller Press UP on controller Press STOP on controller Press DOWN on controller Press UP on controller FT M...

Страница 15: ...otor Response Shade moves DOWN to the bottom limit then pauses Shade moves UP to engage the locking device Motor Response Motor Response Motor Response Shade moves DOWN and UP to engage the Ultra Lock...

Страница 16: ...CONTROLLER Motor Response PRESS UP ON CONTROLLER Motor Response BEEP x3 JOG x3 Motor Response Activated PRESS STOP ON CONTROLLER Motor Response Deactivated ON REMOTE ON SENSOR PRESS P2 ON CONTROLLER M...

Страница 17: ...ce is to far from transmitter Move transmitter to a closer position Power failure Check power supply to motor is connected and active Incorrect wiring Check that wiring is connected correctly refer to...

Страница 18: ...18 Automate Programming Instructions FT Tubular Motors ROLLEASE ACMEDA G 13 NOTES...

Страница 19: ...19 Automate Programming Instructions FT Tubular Motors ROLLEASE ACMEDA 13 NOTES...

Страница 20: ...d Broadmeadows VIC 3047 T 61 3 9355 0100 F 61 3 9355 0110 ROLLEASE ACMEDA USA 200 Harvard Avenue Stamford CT 06902 6320 T 1 203 964 1573 F 1 203 964 0513 ROLLEASE ACMEDA EUROPE Via Conca Del Naviglio...

Отзывы: