Chapter 8. Trigger Settings for Each Pad [TRIGGER]
The following parameters (advanced trigger parameters) are
automatically set to the most efficient values for each pad
when you select the Trigger Type (p. 96), and don’t require
adjustment, except if you experience any of the problems
that are discussed in the explanation of each parameter.
1.
Press the [TRIGGER] button.
The [TRIGGER] button lights.
2.
Press the [F5 (ADVANCE)] button.
If [F5 (ADVANCE)] is not shown, press the [F1 (BANK)] button
once to access the “TRIGGER BANK” screen.
3.
Use the [F1]–[F4] buttons to select the parameter.
4.
Use the [CURSOR (up/down)] buttons to select the
parameter.
5.
Select the pad that you want to edit.
Strike the desired pad, or use the TRIG SELECT buttons to
select it.
You can also use the [CURSOR] buttons to select the pad.
The edit screen for the selected pad will appear.
6.
Use the [-] [+] buttons or the [VALUE] dial to adjust
the setting.
7.
When you’re finished, press the [EXIT] button to
return to the “DRUM KIT” screen.
fig.08-016-scan.eps_70
The graph in the right side of the screen is a “velocity
monitor” that shows the force (velocity) of your strike. It
shows the velocities of the sixteen most recent strikes.
Trigger signal detection time (Scan Time)
Since the rise time of the trigger signal waveform may differ
slightly depending on the characteristics of each pad or
acoustic drum trigger (drum pickup), you may notice that
identical hits (velocity) may produce sound at different
volumes. If this occurs, you can adjust the “Scan Time” so that
your way of playing can be detected more precisely.
fig.ScanTime.e
Scan Time:
0–4.0 (ms)
While repeatedly hitting the pad at a constant force,
gradually raise the Scan Time value from 0 msec, until the
resulting volume stabilizes at the loudest level. At this
setting, try both soft and loud strikes, and make sure that the
volume changes appropriately.
As the value is set higher, the time it takes for the sound
to be played increases. Set this to the lowest value
possible.
Advanced Trigger Parameters
[F5 (ADVANCE)]
Detailed Settings for Trigger Signal
Detection [F1 (SCAN)]
Parameter
Value
Description
Trig Type
Scan Time
0–4.0 (ms)
Trigger signal detection time
Retrig Cancel
1–16
Detecting trigger signal
attenuation
Mask Time
0–64 (ms)
Double triggering prevention
(p. 103)
Time
Scan Time
TD-20X_e.book 102 ページ 2009年6月8日 月曜日 午後3時50分
Содержание V-Drums TD-20X
Страница 1: ... 5 1 0 0 0 0 6 8 6 2 0 1 ...
Страница 2: ...Cover1 4 ...
Страница 153: ...For EU Countries For China TD 20X_e book 153 ページ 2009年6月8日 月曜日 午後3時50分 ...
Страница 155: ...Cover1 4 ...
Страница 156: ... 5 1 0 0 0 0 6 8 6 2 0 1 ...