Replacing Consumable Parts
3
Maintenance
110
OPEN FRONT
COVER
Preparation is complete once the following screen is displayed.
FINISHED?
2.
Replace the separating knife.
A
Remove the separating knife.
1
Loosen the screw until it slips out.
2
Grasp the screw portion, and then slowly pull it out in the direction of the arrow.
When doing this, do not pull it back toward you.
B
Install a new knife.
The knife is secured in place by the magnet.
Magnet
Positioning
groove
C
Slowly insert it into the groove.