WARNING: This procedure
makes the machine operate. Before
you perform this procedure, check
to make sure that operation of the
machine will not create any hazard
or danger.
Press the [ENTER] key.
To go back to the original screen, use the hand wheel to select [Return to main], then press the [ENTER] key.
About the Selection Items
TOOL 1 through TOOL 4:
This grasps the tool holder.
RETURN:
This returns the tool holder to the magazine.
MAGAZINE COVER:
This opens or closes the magazine cover.
LENGTH SCAN:
This executes automatic measurement of tool length.
FORCED RELEASE:
This performs a forced release of the tool holder. Perform the operation while supporting the
tool holder with your hand to keep it from falling.
Automatic Measurement of Tool Length
This performs the same operation as going to VPanel's [Magazine] dialog box and clicking the [Measure All] button. For
detailed information about automatic measurement of tool length, refer to the page indicated below.
☞
P. 59, "4-2 Automatic Measurement of Tool Length"
74
Chapter 6 Handy Panel
6-2 Manual Operation of the ATC