5 Troubleshooting
The marked location isn't where desired.
The center of the base scale may not coincide with the machine's marking origin point.
To correct displacement between the scale center and the marking origin point, follow the steps below.
1
Load an unneeded workpiece that will not be used for
marking on the base. Prepare a workpiece that is about
10 to 20 mm (1/2 to 1 in.) square.
For information on how to load the workpiece, refer to
"2-2 Loading the Workpiece."
2
Start Dr.METAZA2, and in the [Sample] folder, open
[Axis.dmz].
3
Perform marking.
4
Grasp the base on both sides and pull back toward you
to remove.
When doing this, be careful to ensure that the loaded
position of the workpiece does not change.
5
Measure and make a note of the displacement between
the base-scale centerlines and the crossed lines on the
workpiece.
The figure at right shows a positive displacement of 0.5
mm (0.02 in.) for [Width] and a negative displacement
of 0.5 mm (0.02 in.) for [Length].
-0.5 mm
(-0.02 in.)
0.5 mm
(0.02 in.)
Center line
Center line
Material
6
Positive direction
for [Length]
Positive direction
for [Width]
Go into the [Printers] folder. Right-click the [Roland
MPX-60] and open the setting screen for the METAZA
driver.
Windows XP/2000
Click [Printing Preferences].
Windows 98/Me
Click [Properties].