28
Chapter 2 Operation
2-2 Operation of the Blower-fan
Switching the Blower-fan Unit On
The blower-fan unit has no power switch. You switch the blower-fan unit on and off via settings made on the printer.
When you're using the blower-fan unit, set the printer's [BLOWER FAN] menu item to "ENABLE." When this menu item is
set to "ENABLE," the blower fan comes on at the same time when printing starts. When printing ends, the blower fan stops
automatically.
Procedure
Press
.
Press
several times to display the screen shown
on the left.
Press
.
Press
two times to display the screen shown
on the left.
Press
.
Use
to select "ENABLE."
Press
.
Press
in this order to go back to the original screen.
Removing this unit
Before removing this unit, use the procedure described to set the [BLOWER-FAN] menu item to "DISABLE," and turn off the
power switch.
MENU
HEATER MENU
HEATER MENU
BLOWER FAN
BLOWER FAN
DISABLE
ENABLE