50
6 Trouble Shooting
6
Error Message
Meaning
Appears if the number of parameters for a device control instruction is
more than that permissible.
Appears if a framing error, parity error, or overrun error occurs at the
time of data reception. (There is a problem with one of these
settings:Baud Rate, Parity, Stop Bits, or Data Bits.
The protocol settings for the PNC-1860/1410/1210 must be made
correctly in order to match the settings your computer is set to use.
Appears if the I/O buffer has overflowed. (There is a problem with the
connecting cable, or the settings for Heandshaking. Make sure you are
using a cable appropriate for your computer being used.Also, check
that the setting for Handshaking is correct.)
Appears if a communication error other than "Er10" through
"Er16", one uninterpretable by the PNC-1860/1410/1210,
occurs during data communications.
Er14:Termination
Error
Er15:Framing/
Parity Error
Er16:Buffer
Overflow
Er18:
Indeterminate