36
4 Adjustment
4
12
Change the pressure to “
200 g
” with the
[
]
and
[
]
keys. Push the
[ENTER]
key.
- Pen will be in DOWN position.
Force adjust
[ up ] 20g
ENTER
Force adjust
[ up ] 200g
Force adjust
[ down ] 200g
13
14
Change the pressure to “
20 g
” again and make sure the
pressure is 26 ~ 30 gf.
- If not, re-adjust it.
Adjust VR2 on the MAIN BOARD ASS'Y so that the pressure
would be 199 ~ 201 gf when pen tip leaves the BED.
ST-002
BED
PEN CARRIAGE
VR2
MAIN BOARD ASS'Y
ST-012
BED
PEN
CARRIAGE
Содержание CAMM-1 Pro PNC- 1410