Jan. 2012
4
When you measure the OUTPUT L
insert an empty jack on OUTPUT R.
When you measure the OUTPUT R
insert an empty jack on OUTPUT L.
CH1 = OUTPUT LEFT
It must be 1000hz (
±
20)
It must be 6.00 Vpk (
±1
.00 Vpk)
CH2 = OUTPUT RIGHT
It must be 1000hz (
±
20)
It must be 3.00 Vpk (
±
0.50 Vpk)
OSCILLOSCOPE SETUP:
Volt div. = 5.00V / Time div. = 1.00ms
1.
Produce following wave with external Waveform generator:
Wave generator OUT L:
Freq =1Khz (sine wave)
Amplitude=2,5Vpp (measured with cable not connected to BK-5)
Wave generator OUT R:
Freq =1Khz (sine wave)
Amplitude=2,5Vpp (measured with cable not connected to BK-5)
2.
Check the following values on the oscilloscope:
3.
Keep pressed
VARIATION 1]
button and verify that the waveforms are completely nil:
6.
Press
[START/STOP]
button to go to next test.
16. Noise check
The display shows:
Setting:
•
Remove all connections from BK-5 sockets.
•
Connect the mono audio cable first from
OUTPUT L/MONO
then from
OUTPUT R
to Noise Meter’s input.