39
DALIS PRO
DOMESTIC HOT WATER HEAT PUMP
EN
The heat pump will start working to reach the set temperature (SET TEMP). If the set
temperature is higher than 65 °C, the electric heater will switch on as a support source to
reach the set temperature.
If the outside air temperature is below -10 °C or above 44 °C, the water will be heated by
the electric heater only.
While the heat pump is operating with low outdoor air temperature, the anti-freeze mode
can be activated automatically to melt the ice accumulated on the evaporator.
12.7. Water temperature setting
While the heat pump is running, use the buttons
to set the desired water temperature.
The maximum temperature achievable with the heat pump alone depends directly on the
inlet air temperature. See the temperature and performance table below:
Inlet air temperature (ºC)
Temperature reached by the
heat pump
Temperature reached by electrical heating
element
Temperature reached by electrical
heating element
Temperature reached by electrical
heating element
Temperature of water (ºC)
If the set temperature (via the control panel) is higher than the temperature achievable by
the heat pump alone (shown in the graph), the electric heater will automatically switch on
to reach this temperature.
IMPORTANT
To reduce energy consumption, avoid setting temperatures above 55°C if it is not necessary.
12.8. Switching off the equipment
To turn off the heat pump, press and hold the button
for 2 seconds while the equipment
is running.