28
10.2. Parameter list
Checking parameters: When the unit is on, press button
and hold for 5 seconds to entry
the system parameter view.
Adjusting parameters: When the unit is off (standby), press simultaneously
&
for 5
seconds to entry the parameter adjusting interface. A password is necessary to change the
parameters.
Parame-
ter
Visibility:
U=user
I=installer
Description
Range
Default
Remarks
Adjustable parameters
0
I/U
Tank water
setting temp.
TS1
10 ~ 65°C
Adjust
Adjustable
1
I
Water temp
difference
TS6
2 ~ 15°C
5°C
Adjustable
2
I
E-heater off tank
water temp
TS2
10 ~ 90°C
65°C
Adjustable
3
I
E-heater delay
time
t1
0 ~ 90min
6
t * 5 min
4
I
Week
disinfection
temperature.
TS3
50 ~ 70°C
70°C
Adjustable
5
I
High temp
disinfection time
t2
0 ~ 90 min
30 min
Adjustable
13
I
Disinfection start
up time adjusting
0 ~ 23
23:00 h
Adjustable
(hour)
14
I
Type of water
pump
0/1/2
0
0: no water pump 1:
(circulation pump)
2: (solar water
pump)
15
I
Setting
circulation water
temperature
15 ~ 50°C
35°C
Adjustable
16
I
The temperature
difference
to start the
circulation water
pump
1-15°C
2°C
Adjustable