37
DALIS
Digital electric unvented heat pump
Description
Code
Unit
Min.
Max.
Default
Notes
Evaporator temper-
ature to conclude
defrosting procedure
(only if P4=1)
d2
ºC / ºF
-50.0
50.0
3.0
Maximum duration of
defrosting procedure
d3
min
0
99
20
Automatic defrosting
start threshold (evap-
orator temperature)
d17
ºC / ºF
-50.0
50.0
-2.0
Minimum compressor
start up time to start
deforsting procedure
d18
min
0
240
60
Minimum level probe
alarm (only AL1
warning)
A0
----
0
2
0
0 = upper probe
1 = lower probe
2 = evaporator probe
Minimum alarm set
(only AL1 warning)
A1
ºC / ºF
0.0
50.0
10.0
Type of minimum
level alarm (only AL1
warning)
A2
----
0
1
0
0 = disabled
1 = absolute
Maximum level
probe alarm (only AH
warning)
A3
----
0
2
0
0 = upper probe
1 = lower probe
2 = evaporator probe
Maximum alarm set
(only AH warning)
A4
ºC / ºF
0.0
199.0
90.0
Type of maximum
level alarm delay
(only AH warning)
A5
----
0
1
0
0 = disabled
1 = absolute
Minimum level AL1
alarm delay due to
equipment start-up
(only warning)
A6
min
0
240
120
AL1 and AH temper-
ature alarm delays
(only warning)
A7
min
0
240
15
Alarm hysteresis
A11
min
0.1
30.0
2.0
Heating element start
up interval (anti-
legionella)
H0
days
0
99
30
Anti-legionella
function set
H1
ºC / ºF
10.00
199.0
60.0
Duration of anti-
legionella cycle
H3
min
0
240
2
Solar thermal input
enabling (digital 1)
i0
----
0
2
2
0 = input disabled
1 = pressure input
2 = digital 1 input