background image

3

 Smart Check by ROHO Operation Manual 

Important Safety Information, Continued

Warnings, Continued

•  Using an accessory (for example, a pump or a cushion cover) other than those provided by ROHO, Inc., may be 

unsafe and could void the product warranty.  

•  DO NOT modify Smart Check or any components. Doing so may result in damage to the product and will void the 

warranty. 

 

DO NOT use in the presence of flammable anesthetics and/or in an oxygen-rich environment. Doing so will 
increase the risk of fire or explosion.

 

If your cushion feels unstable during Smart Setup, perform a Hard Reset and then repeat Smart Setup. If you 

still feel unstable, perform an Optional Setup and consult with a healthcare provider.

 

The cushion MUST be properly sized to the user. IF IT IS NOT, Smart Check may not find the individual’s inflation 

range during Smart Setup, reducing or eliminating the benefits of the cushion and increasing the risk to skin 

and other soft tissue.

 

All aspects of Smart Check use described in this manual can be performed by the individual or by a caregiver. If 
you are unable to perform any tasks described in this manual, seek assistance.

 

BURN HAZARD: If ambient temperature exceeds 47°C (117°F), DO NOT maintain contact with product surface for 
more than ten (10) minutes. 

 

Smart Check MUST be used ONLY with a compatible ROHO cushion cover. Use of a different cover may interfere 
with the accuracy of Smart Check functions.

 

DO NOT perform maintenance on Smart Check while it is in use. Doing so may result in improper functioning.

 

Set up your cushion in the usual environmental conditions. Perform Check when environmental conditions, 
including temperature and altitude, change significantly.

Cautions

•  Daily: Inspect Smart Check quick disconnect, tubing, and device housing for wear or breakage, and to ensure inter-

component attachment. DO NOT continue to use Smart Check if any part is damaged or cannot be attached securely. 
ROHO, Inc. recommends that Smart Check be inspected periodically by a qualified technician.

•  DO NOT submerge Smart Check in liquid, as it will damage the device.
•  Protect Smart Check from blunt force shocks that may cause damage and/or breakage.
•  DO NOT expose the product to high heat, open flames, or hot ashes. 
•  DO NOT use the inflation valve or any Smart Check components as a handle for carrying or for pulling the cushion.
•  Prolonged exposure to ozone may degrade some of the materials used in the manufacture of this product, affect the 

performance of this product, and void the product warranty. 

•  Prolonged exposure to UV light / sunlight may cause product labels to fade. 

DRAFT

Содержание Smart Check

Страница 1: ...l must be given to the user of this product Operator Individual or Caregiver Before using this product read instructions and save for future reference s h a p e f i t t i n g t e c h n o l o g y Operation Manual D R A F T ...

Страница 2: ...tsch 37 ROHO Inc 100 North Florida Avenue Belleville Illinois 62221 5429 U S A 800 851 3449 Fax 888 551 3449 Customer Care cc roho com Outside the U S A 618 277 9150 Fax 618 277 6518 intl roho com ROHO com 2015 ROHO Inc The following are trademarks and registered trademarks of ROHO Inc ROHO Sensor Ready shape fitting technology and Smart Check Products in this manual may be covered by one or more ...

Страница 3: ...ncrease risk to skin and other soft tissue Using a cushion that is not a ROHO Sensor Ready Cushion may also result in damage to Smart Check and will void the warranty DO NOT use an under inflated cushion or an over inflated cushion because the product benefits will be reduced or eliminated resulting in an increased risk to skin and other soft tissue If the cushion does not appear to be holding air...

Страница 4: ... NOT maintain contact with product surface for more than ten 10 minutes Smart Check MUST be used ONLY with a compatible ROHO cushion cover Use of a different cover may interfere with the accuracy of Smart Check functions DO NOT perform maintenance on Smart Check while it is in use Doing so may result in improper functioning Set up your cushion in the usual environmental conditions Perform Check wh...

Страница 5: ...ring location Keep dry Wipe by hand Air dry Do not use bleach Low battery amber light Temperature Limit Humidity Limitation relative non condensing Atmospheric Pressure Limitation Choking hazard Do not discard in household trash User identification IEC 60601 1 Type BF Applied Part 0 6 D R A F T ...

Страница 6: ...dard C22 2 No 60601 1 Electromagnetic interference is not caused by Smart Check and does not interfere with Smart Check Expected Service Life 5 years Batteries one 1 year typical operating time Smart Check is an IP54 rated device protected from dust and splashing water Parts Detail Package Contents Smart Check by ROHO Smart Check instructions registration card storage case Product Registration Mai...

Страница 7: ...ative to Smart Setup Optional Setup may be preferred in the following situations A qualified seating specialist has determined an alternate immersion and envelopment level for the individual The individual must accommodate needs such as severe asymmetrical posture that are beyond the immersion and envelopment setting found by Smart Check during Smart Setup The cushion is being used on an upholster...

Страница 8: ... Smart Setup Red Light Remove air Green Light Setup is complete Red Light Add air Setup Button Check Button 3 Sit in the chair in your usual position Pull to remove the tab first time use only 4 Make sure the inflation valve is closed Attach Smart Check to the cushion You will hear a click when the connection is secure 1 Place the cushion in the chair Place the nozzle of the pump over the inflatio...

Страница 9: ... air approximately 30 to 60 seconds and wait for the flashing green light If the red down arrow light stops flashing before you have opened the valve go back to 5a To ensure an accurate reading Remain still and avoid restricting air flow while you release air from the cushion 5a Press the Check Button When you see the red down arrow light proceed to step 5b NOTE If you see the red up arrow light w...

Страница 10: ...istributed Perform a weight shift to circulate air in the cushion then press the Check Button to get a new reading The quick disconnect is not securely attached to the cushion Make sure the connection is secure then press the Check Button to get a new reading See Troubleshooting in this manual The cushion needs more air Open the valve and add more air to the cushion 6 to 10 pumps Close the valve P...

Страница 11: ...is closed Press the Check Button to activate Smart Check You will see either a or a red light DO NOT add or remove air Store Smart Check in a safe and accessible location See Disconnection and Storage instructions 4s 6 Press and hold the Setup Button for four 4 seconds until you see a green light The green light means that your preferred cushion inflation setting has been saved The green light DOE...

Страница 12: ...e the batteries if needed Contact Customer Care if the issue continues Smart Setup After you press the Check Button Smart Check still displays the red add air light but you have confirmed that the cushion is overinflated and that the quick disconnect is securely attached Inspect the O ring on the cushion s quick disconnect for wear or damage If damage is found contact Customer Care Inspect the cus...

Страница 13: ... in accordance with the applicable regulations in your jurisdiction including electronic waste disposal DO NOT INCINERATE Battery Replacement The low battery light means the batteries should be replaced Smart Check will remember your saved setting after battery replacement To preserve battery life Smart Check automatically goes into sleep mode when not in use Expected service life of batteries one...

Страница 14: ...ing Shipping Address 1501 South 74th Street Belleville IL 62223 5900 USA Administrative Offices 100 N Florida Avenue Belleville IL 62221 5429 USA U S 800 851 3449 Fax 888 551 3449 Outside the U S 618 277 9150 Fax 618 277 6518 ROHO com D R A F T ...

Отзывы: