background image

2

 Smart Check by ROHO Operation Manual 

Intended Use

 

Smart Check

 by ROHO

®

 (Smart Check) is a cushion feedback system that is intended to assist the user by saving an 

inflation range during cushion setup. During subsequent inflation level checks, Smart Check is intended to indicate 
whether adjustments are needed to remain in the saved range.  

Smart Check must be connected to a ROHO

®

 Single Compartment Cushion with Sensor Ready

 Technology (Sensor 

Ready Cushion).

Important Safety Information

•  Read this instruction manual carefully and completely before using the product.
•  ROHO medical products are intended to be part of an overall care regimen. ROHO, Inc. recommends that a clinician 

make product recommendations based upon an evaluation of the individual’s medical and therapeutic needs and 
overall condition (for example, potential allergic reactions). Use of this device does not eliminate routine inspection 
of the product and all normal activities associated with skin and soft tissue protection (weight shifts, skin 
inspection, overall skin care, etc.)

Warnings

•  Smart Check by ROHO has been designed for use only with the ROHO Sensor Ready Cushion. Using a cushion 

that is not a ROHO Sensor Ready Cushion will affect Smart Check functions, reduce or eliminate the benefits of 
the cushion, and increase risk to skin and other soft tissue. Using a cushion that is not a ROHO Sensor Ready 
Cushion may also result in damage to Smart Check and will void the warranty.

•  DO NOT use an under-inflated cushion or an over-inflated cushion because the product benefits will be reduced 

or eliminated, resulting in an increased risk to skin and other soft tissue. If the cushion does not appear to be 
holding air, or if you are not able to inflate or deflate the cushion, see the 

T

roubleshooTing

 section of the manual 

that was provided with the cushion. Immediately contact your clinical caregiver, distributor, or ROHO, Inc. if the 
problem persists.

•  Check inflation frequently, at least once a day, using the Smart Check or a hand check.  

 

Perform Smart Setup or Optional Setup again if the following changes occur: 1) a different individual is 
using Smart Check; 2) a different chair or a different cushion is being used; or 3) the individual experiences 
physiological changes (for example, weight loss or weight gain). Before performing a new Setup, you must clear 
your Smart Check setting; see 

h

ard

 r

eseT

 i

nsTrucTions

.

 

 

KEEP BATTERIES OUT OF REACH OF CHILDREN AND ANY INDIVIDUALS WHO HAVE A TENDENCY TO PLACE INEDIBLE 
OBJECTS IN THEIR MOUTHS.  Swallowing or inhalation may lead to serious injury or death. IMMEDIATELY seek 
emergency medical assistance.

•  USE CAUTION when in presence of children to avoid a strangulation hazard. Detach Smart Check when not in 

use and store in a safe and accessible location.

DRAFT

Содержание Smart Check

Страница 1: ...l must be given to the user of this product Operator Individual or Caregiver Before using this product read instructions and save for future reference s h a p e f i t t i n g t e c h n o l o g y Operation Manual D R A F T ...

Страница 2: ...tsch 37 ROHO Inc 100 North Florida Avenue Belleville Illinois 62221 5429 U S A 800 851 3449 Fax 888 551 3449 Customer Care cc roho com Outside the U S A 618 277 9150 Fax 618 277 6518 intl roho com ROHO com 2015 ROHO Inc The following are trademarks and registered trademarks of ROHO Inc ROHO Sensor Ready shape fitting technology and Smart Check Products in this manual may be covered by one or more ...

Страница 3: ...ncrease risk to skin and other soft tissue Using a cushion that is not a ROHO Sensor Ready Cushion may also result in damage to Smart Check and will void the warranty DO NOT use an under inflated cushion or an over inflated cushion because the product benefits will be reduced or eliminated resulting in an increased risk to skin and other soft tissue If the cushion does not appear to be holding air...

Страница 4: ... NOT maintain contact with product surface for more than ten 10 minutes Smart Check MUST be used ONLY with a compatible ROHO cushion cover Use of a different cover may interfere with the accuracy of Smart Check functions DO NOT perform maintenance on Smart Check while it is in use Doing so may result in improper functioning Set up your cushion in the usual environmental conditions Perform Check wh...

Страница 5: ...ring location Keep dry Wipe by hand Air dry Do not use bleach Low battery amber light Temperature Limit Humidity Limitation relative non condensing Atmospheric Pressure Limitation Choking hazard Do not discard in household trash User identification IEC 60601 1 Type BF Applied Part 0 6 D R A F T ...

Страница 6: ...dard C22 2 No 60601 1 Electromagnetic interference is not caused by Smart Check and does not interfere with Smart Check Expected Service Life 5 years Batteries one 1 year typical operating time Smart Check is an IP54 rated device protected from dust and splashing water Parts Detail Package Contents Smart Check by ROHO Smart Check instructions registration card storage case Product Registration Mai...

Страница 7: ...ative to Smart Setup Optional Setup may be preferred in the following situations A qualified seating specialist has determined an alternate immersion and envelopment level for the individual The individual must accommodate needs such as severe asymmetrical posture that are beyond the immersion and envelopment setting found by Smart Check during Smart Setup The cushion is being used on an upholster...

Страница 8: ... Smart Setup Red Light Remove air Green Light Setup is complete Red Light Add air Setup Button Check Button 3 Sit in the chair in your usual position Pull to remove the tab first time use only 4 Make sure the inflation valve is closed Attach Smart Check to the cushion You will hear a click when the connection is secure 1 Place the cushion in the chair Place the nozzle of the pump over the inflatio...

Страница 9: ... air approximately 30 to 60 seconds and wait for the flashing green light If the red down arrow light stops flashing before you have opened the valve go back to 5a To ensure an accurate reading Remain still and avoid restricting air flow while you release air from the cushion 5a Press the Check Button When you see the red down arrow light proceed to step 5b NOTE If you see the red up arrow light w...

Страница 10: ...istributed Perform a weight shift to circulate air in the cushion then press the Check Button to get a new reading The quick disconnect is not securely attached to the cushion Make sure the connection is secure then press the Check Button to get a new reading See Troubleshooting in this manual The cushion needs more air Open the valve and add more air to the cushion 6 to 10 pumps Close the valve P...

Страница 11: ...is closed Press the Check Button to activate Smart Check You will see either a or a red light DO NOT add or remove air Store Smart Check in a safe and accessible location See Disconnection and Storage instructions 4s 6 Press and hold the Setup Button for four 4 seconds until you see a green light The green light means that your preferred cushion inflation setting has been saved The green light DOE...

Страница 12: ...e the batteries if needed Contact Customer Care if the issue continues Smart Setup After you press the Check Button Smart Check still displays the red add air light but you have confirmed that the cushion is overinflated and that the quick disconnect is securely attached Inspect the O ring on the cushion s quick disconnect for wear or damage If damage is found contact Customer Care Inspect the cus...

Страница 13: ... in accordance with the applicable regulations in your jurisdiction including electronic waste disposal DO NOT INCINERATE Battery Replacement The low battery light means the batteries should be replaced Smart Check will remember your saved setting after battery replacement To preserve battery life Smart Check automatically goes into sleep mode when not in use Expected service life of batteries one...

Страница 14: ...ing Shipping Address 1501 South 74th Street Belleville IL 62223 5900 USA Administrative Offices 100 N Florida Avenue Belleville IL 62221 5429 USA U S 800 851 3449 Fax 888 551 3449 Outside the U S 618 277 9150 Fax 618 277 6518 ROHO com D R A F T ...

Отзывы: