1. BEFORE YOU BEGIN 

1.1 PRODUCT DESCRIPTION 

The dehumidifier is used to remove excessive moisture from the air. The resulting reduction 

in relative humidity protects buildings and their contents from the adverse effects of excess 

humidity. 

The  environmentally  friendly  R290  is  used  as  the  refrigerant.  R290  has  no  damaging 

influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available 

worldwide. Because of its efficient energy properties, R290 is highly suitable as a coolant 

for  this  application.  Special  precautions  must  be  taken  into  consideration  due  to  the 

coolant's high flammability. 

 

1.2SYMBOLS FROM THE UNIT AND USER MANUAL 

 

warning

 

This unit uses a flammable refrigerant.  

If refrigerant leaks and comes in contact with fire or heating part, it 
will create harmful gas and there is risk of fire. 

 

Read the USER MANUAL carefully before operation. 

 

Further  information  is  available  in  the  USER  MANUAL,  SERVICE 

MANUAL, and the like. 

 

Service personnel are required to carefully read the USER MANUAL 
and SERVICE MANUAL before operation. 

Содержание R-9424

Страница 1: ...1 Home Dehumidifier User Manual Original instructions R 9424 With R290 refrigerant...

Страница 2: ...2 2 4 Checking for presence of refrigerant 7 2 2 5 Presence of fire extinguisher 7 2 2 6 No ignition sources 7 2 2 7 Ventilated area 7 2 2 8 Checks to the refrigeration equipment 7 2 2 9 Checks to el...

Страница 3: ...3 8 TROUBLESHOOTING 18 9 SAFETY WARNING 19...

Страница 4: ...of its efficient energy properties R290 is highly suitable as a coolant for this application Special precautions must be taken into consideration due to the coolant s high flammability 1 2SYMBOLS FRO...

Страница 5: ...refrigerant The refrigerant loop is sealed Only a qualified technician should attempt to service Do not discharge the refrigerant into the atmosphere R 290 propane is flammable and heavier than air It...

Страница 6: ...omponent parts are designed for propane and non incentive and non sparking Component parts shall only be replaced with identical repair parts FAILURE TO ABIDE BY THIS WARNING COULDRESULT IN AN EXPLOSI...

Страница 7: ...product identification plate Always use a power outlet that is grounded Unplug the power cord when cleaning or when not in use Do not operate with wet hands Prevent water from spilling onto the unit...

Страница 8: ...not be installed in an unventilated space if that space is smaller than 8 m Compliance with national gas regulations shall be observed Keep any required ventilation openings clear of obstruction The...

Страница 9: ...pheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants i e no sparking adequately sealed or intrinsically safe 2 2 5 Presence of fire extinguisher I...

Страница 10: ...illegible shall be corrected refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unl...

Страница 11: ...air circulation 2 Never install the unit where it could be subject to Heat sources such as radiators heat registers stoves or other products that products that produce heat in an area where oil or wat...

Страница 12: ...e unit in rooms which exceed4 m Do not install the unit in a place where inflammable gas may leak NOTE The manufacturer may provide other suitable example or may provide additional information about t...

Страница 13: ...ast 24 hours before start up Keep doors and windows close for better energy saving Do not operate or store the unit in direct sunlight or rain It is normal for air outlet to feel warm to touch after c...

Страница 14: ...14 4 PRODUCT OVERVIEW 4 1 FRONT VIEW BACK VIEW Control Panel Air Outlet Caster s Front Cover Filter Frame Back Cover Continuous Drain Plug Water Tank...

Страница 15: ...to shut off auto restart Effectively removes moisture dust and dust mites from the air 1 24 hour timer to set the time of operation 4 3 SPECIFICATIONS MODEL R 9424 Rated Capacity 24L day 30 80 RH Powe...

Страница 16: ...or stop 4 Fan speed button Press to select fan speed between high and low 5 Hum button Adjusts the humidity set point within the range of 30 80 6 Purify Lock button Press this button to turn on off pu...

Страница 17: ...the target humidity will increase by 5 and the cycle will be 30 to 80 Purify Child lock Press this button to turn on or off the purifying function hold it for 3 seconds to turn on or off the child loc...

Страница 18: ...Touch the sleep button and the button light will be on to activate the sleep function Long press the sleep button to start the filter reset function 5 3 SETTINGS INDICATOR LIGHT Power indicator light...

Страница 19: ...r that the water is full The unit will stop working automatically when the tank is full ION CARBON indicator light Reset Sleep When the ION CARBON filter reaches its service life after one year this i...

Страница 20: ...into place within the dehumidifier After you have replaced the tank plug the unit back into its power source If the water tank is very dirty wash it with cold warm water Do not use detergent steel wi...

Страница 21: ...d clear of obstruction Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of the unit Do not submerge the end of hose into water otherwiseit can cause Air Lock...

Страница 22: ...frame from the back cover and gently absorb the dust on the screen frame surface with a vacuum cleaner 2 If the screen frame is very dirty wipe it with warm water and soft detergent and dry it thorou...

Страница 23: ...er is blocked Clean the filter screen according to the dehumidifier cleaning instructions Whether the inlet or outlet is blocked Remove the blockage from the inlet or outlet Whether the setting humidi...

Страница 24: ...per the following steps 1 Unplug the unit 2 Empty the water tank and dry with a cloth 3 Clean the filter and let the filter dry completely in a shaded area 4 Collect the power cord at the tank and re...

Страница 25: ...ste collection centre or to a dealer providing this service Disposing of a household appliance separately avoids possible negative consequences for the environment and health deriving form inappropria...